D4NL-1AFA-B Omron, D4NL-1AFA-B Datasheet - Page 7

SAFETY SWITCH

D4NL-1AFA-B

Manufacturer Part Number
D4NL-1AFA-B
Description
SAFETY SWITCH
Manufacturer
Omron
Datasheets

Specifications of D4NL-1AFA-B

Contact Voltage Ac Max
240V
Contact Voltage Dc Max
24V
Contact Current Ac Max
10A
Contact Current Dc Max
200mA
Switch Terminals
Screw
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
EN60747-5-1, IEC 947-5-1, EN1088,
Contact Configuration
SPST-NC / SPST-NO
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Operation Method
Nomenclature
Note: Terminal numbers vary with the model.
Shorting pin (12-41)
Operation key hole
Mechanical
lock models
Solenoid
lock models
Door open/closed
detection switch
Terminal 31/33
Terminal 32/34
Operation Principles
Structure
Terminal 42
Terminal 41
Terminal 12
Terminal 11
Terminal 21
Terminal 22
Operation Key
Operation Key
Plunger
Release key
Conduit opening
(vertical)
Lock plate
Lock plate
OFF
OFF
Spring
Spring
Terminal 51/53
Solenoid
Solenoid
Lock monitor switch
Solenoid
Terminal E1 (+)
Terminal E2 (−)
Terminal 01
Indicator
Terminal 02
Conduit opening
(horizontal)
Terminal 52/54
When the Operation Key is inserted, it is
locked by the lock spring. The door will stay
locked even if there is a power interruption.
If the solenoid is OFF, the door will not be
locked when the Operation Key is inserted.
This means that the door can be opened
and closed easily when replacing work-
pieces or parts.
The head can be
mounted in 3 directions.
Standard Release Key
(Bottom View)
OFF
OFF
Guard Lock Safety-door Switch
UNLOCK
LOCK
The solenoid is released only when the
lock is turned ON.
The door is locked only when the solenoid
is turned ON. This means that the door will
be unlocked if there is a power interruption
and so this model cannot be used in sys-
tems that would maintain a hazardous
state (e.g., systems requiring toxic gases,
high temperatures, or gears that would
continue to turn due to inertia).
Special Release Key
UNLOCK
Special release key
Two conduits
(horizontal and vertical)
Back-mounting is also possible.
(Bottom View)
D4NL
ON
ON
LOCK
7