Specifications of D4NL-1AFA-B

Contact Voltage Ac Max
240V
Contact Voltage Dc Max
24V
Contact Current Ac Max
10A
Contact Current Dc Max
200mA
Switch Terminals
Screw
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
EN60747-5-1, IEC 947-5-1, EN1088,
Contact Configuration
SPST-NC / SPST-NO
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
AA-58
• Contains no harmful substances, such as lead, cadmium or
• Models with 4-contact and 5-contact built-in Switches are
• Key holding force of 1,300 N minimum.
• Can be used for either standard loads or microloads.
• Lineup includes models with a conduit size of M20.
• IP67 degree of protection.
hexavalent chromium, reducing the burden on the environment.
available.
1:
2:
4:
A:
B:
C:
D:
E:
F:
G:
H:
F:
D:
A:
B:
C:
G:
H:
J:
Be sure to read the “Safety Precautions” on page A-63 and the
“Precautions for All Safety Door Switches” on page A-2.
Pg13.5
G1/2
M20
1NC/1NO slow-action contacts plus 1NC/1NO slow-action
contacts
1NC/1NO slow-action contacts plus 2NC slow-action
contacts
2NC slow-action contacts plus 1NC/1NO slow-action
contacts
2NC slow-action contacts plus 2NC slow-action contacts
2NC/1NO slow-action contacts plus 1NC/1NO slow-action
contacts
2NC/1NO slow-action contacts plus 2NC slow-action
contacts
3NC slow-action contacts plus 1NC/1NO slow-action
contacts
3NC slow-action contacts plus 2NC slow-action contacts
Four mounting directions possible (Front-side mounting at
time of delivery)/plastic
Four mounting directions possible (Front-side mounting at
time of delivery)/metal
Mechanical lock/24-VDC solenoid release
Mechanical lock/110-VAC solenoid release
Mechanical lock/230-VAC solenoid release
24-VDC solenoid lock/mechanical release
110-VAC solenoid lock/mechanical release
230-VAC solenoid lock/mechanical release
@@@@ @@@
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA
Tel. 1/888/510-4357
Canada
Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
\
8. NPT, 1/2”-14 NPT Conduit
Adapter included
(Applicable to M20 Conduit models only)
B:
Blank: Standard
4:
Blank: Bottom
S:
1:
2:
3:
5:
Models with M20 conduits are also available with an M20 to
1/2-14NPT Adaptor.
10 to 115 VAC/VDC (orange LED indicator)
Special release key
Vertical mounting
Adjustable mounting (horizontal)
Adjustable mounting (horizontal/vertical)
Front
Horizontal mounting
@

Related parts for D4NL-1AFA-B

D4NL-1AFA-B Summary of contents

Page 1

... NPT, 1/2”-14 NPT Conduit Adapter included (Applicable to M20 Conduit models only) Models with M20 conduits are also available with an M20 to 1/2-14NPT Adaptor Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (horizontal) 5: Adjustable mounting (horizontal/vertical) For the Latest Information Tel. 1/866/986-6766 On the Internet: www.sti.com or www.omron.ca @ ...

Page 2

... Solenoid lock 1NC/1NO+1NC/1NO Mechanical release 1NC/1NO+2NC 2NC+1NC/1NO 2NC+2NC 2NC/1NO+1NC/1NO 2NC/1NO+2NC 3NC+1NC/1NO 3NC+2NC For the Latest Information On the Internet: www.sti.com or www.omron.ca D4NL Guard Lock Safety-door Switch Pg13.5 D4NL-1AFA-B G1/2 D4NL-2AFA-B M20 D4NL-4AFA-B Pg13.5 D4NL-1BFA-B G1/2 D4NL-2BFA-B M20 D4NL-4BFA-B Pg13.5 D4NL-1CFA-B G1/2 D4NL-2CFA-B ...

Page 3

... Solenoid lock 1NC/1NO+1NC/1NO Mechanical release 1NC/1NO+2NC 2NC+1NC/1NO 2NC+2NC 2NC/1NO+1NC/1NO 2NC/1NO+2NC 3NC+1NC/1NO 3NC+2NC For the Latest Information Tel. 1/866/986-6766 On the Internet: www.sti.com or www.omron.ca Pg13.5 D4NL-1AFA-B4 G1/2 D4NL-2AFA-B4 M20 D4NL-4AFA-B4 Pg13.5 D4NL-1BFA-B4 G1/2 D4NL-2BFA-B4 M20 D4NL-4BFA-B4 Pg13.5 D4NL-1CFA-B4 G1/2 D4NL-2CFA-B4 M20 D4NL-4CFA-B4 Pg13 ...

Page 4

... Tel. 1/866/986-6766 On the Internet: www.sti.com or www.omron.ca Guard Lock Safety-door Switch 3 A 0.27 A 240 V 250 7,200 VA 720 2.5 A 0. 0.27 A 0.27 A +10% 24 VDC 110 VAC 10% 230 VAC 10% 10% Approx. 200 mA Approx Approx Class F (130 C max 115 VAC/VDC Approx Orange D4NL 69 VA AA-61 ...

Page 5

... The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4NL in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. ...

Page 6

... Indicates conditions where the Key is inserted and the lock is applied. Terminals 12 and 41 are connected internally (as per GS-ET-19). D4NL-@AF@-@ 1NC/1NO + 1NC/1NO D4NL-@BF@-@ 1NC/1NO + 2NC D4NL-@CF@-@ 2NC + 1NC/1NO D4NL-@DF@-@ 2NC + 2NC D4NL-@EF@-@ 2NC/1NO + 1NC/1NO D4NL-@FF@-@ 2NC/1NO + 2NC D4NL-@GF@-@ 3NC + 1NC/1NO D4NL-@HF@-@ 3NC + 2NC OMRON SCIENTIFIC TECHNOLOGIES, INC. USA Canada Tel. 1/888/510-4357 Tel. 1/866/986-6766 Lock position 11- ...

Page 7

... D4NL Guard Lock Safety-door Switch 10 to 115 VAC/VDC Constant-current diode @ @@ Terminals 12 and 41 are connected internally and so connect terminals 11 and 42 for safety-circuit input. (GS-ET-19). Connect terminals 21 and 22 and terminals 51 and 52 in series when using as safety-circuit input (redundancy circuit for terminals 11 and 12 and terminals 41 and 42 above). Connect the terminals individually when using as auxiliary-circuit input (e ...

Page 8

... Terminal 52/54 Terminal 51/53 UNLOCK LOCK For the Latest Information On the Internet: www.sti.com or www.omron.ca D4NL Guard Lock Safety-door Switch ON The solenoid is released only when the lock is turned ON. ON The door is locked only when the solenoid is turned ON. This means that the door will ...

Page 9

... D4NL Guard Lock Safety-door Switch All units are in millimeters unless otherwise indicated. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC). Confirm performance before application. @@@@ 30.5 Pre-travel distance ...

Page 10

... Conduit cap LOCK Conduit opening Black 6.3 20 Black For the Latest Information On the Internet: www.sti.com or www.omron.ca D4NL Guard Lock Safety-door Switch @@@@ 15 N max max max min. @@@@ 15 N max max max min dia. 4.5 dia. 8 dia. 24.6 22 ...

Page 11

... D4NL Guard Lock Safety-door Switch Red Black 44 min 46.5 max Key insertion position 44 min 46.5 max Key insertion position 45 min 47.5 max Key insertion position Red Black 45 min 47.5 max Key insertion position OMRON SCIENTIFIC TECHNOLOGIES, INC. USA Canada Tel. 1/888/510-4357 ...

Page 12

... KM1 and KM2: Magnetic Contactor M: 3-phase motor Feedback loop Off delay Control timer circuit Guard opens Operation instruction Motor controller Guard can be opened The above example circuit is for Category 3. For the Latest Information On the Internet: www.sti.com or www.omron.ca D4NL Guard Lock Safety-door Switch @ AA-69 ...

Page 13

... D4NL Guard Lock Safety-door Switch Lock signal OPEN 11 Operation signal A1 A2 T11 T21 Limit switch S1 Guard Lock Safety-door Switch S2 Operation signal Lock signal K1 and K2 (NC) K1 and K2 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO) OMRON SCIENTIFIC TECHNOLOGIES, INC. USA Canada Tel. 1/888/510-4357 ...

Page 14

... N·m 0.49 to 0.59 N·m 2.35 to 2.75 N·m 0.49 to 0.69 N·m 1.77 to 2.16 N·m 1.27 to 1.67 N·m D4DS-K1/-K2 (Horizontal/Vertical Mounting) 32 Two, M4 0.1 15 0.1 55 0.1 D4DS-K3 (Adjustable Mounting: Horizontal) Two 0.1 40 0.1 D4DS-K5 (Adjustable Mounting: Vertical) Two or, 43 0.1 0.1 D4NL AA-71 ...

Page 15

... D4NL Guard Lock Safety-door Switch Switch the release key to the UNLOCK position. Remove the four screws of the head to enable changing the mounting direction of the head. The head can be mounted in four directions. Ensure that no foreign material enters the interior of the Switch. Also, insert the head until the insertion line engraved on the head is hidden by the reference line on the Switch, as shown in the following diagram ...

Page 16

... The D4DL Series was discontinued from the end of November 2003. Use D4NL-series Switches as substitutes. The D4DL and D4NL have basically the same structure, and use the same mounting method and Operation Keys. There are differences, however, in the external appearance and the mounting sections. ...

Page 17

... D4NL-2AFC-B, D4NL-2BFC-B D4DL-1DFC-E* D4NL-1CFC-B, D4NL-1DFC-B D4DL-2DFC-E* D4NL-2CFC-B, D4NL-2DFC-B D4DL-1CFJ-E* D4NL-1AFJ-B, D4NL-1BFJ-B D4DL-2CFJ-E* D4NL-2AFJ-B, D4NL-2BFJ-B D4DL-1DFJ-E* D4NL-1CFJ-B, D4NL-1DFJ-B D4DL-2DFJ-E* D4NL-2CFJ-B, D4NL-2DFJ-B D4DL-1CFA-B-HT D4NL-1AFA-B4, D4NL-1BFA-B4 D4DL-2CFA-B-HT D4NL-2AFA-B4, D4NL-2BFA-B4 D4DL-1DFA-B-HT D4NL-1CFA-B4, D4NL-1DFA-B4 D4DL-2DFA-B-HT D4NL-2CFA-B4, D4NL-2DFA-B4 D4DL-1CFG-B-HT D4NL-1AFG-B4, D4NL-1BFG-B4 D4DL-2CFG-B-HT D4NL-2AFG-B4, D4NL-2BFG-B4 D4DL-1DFG-B-HT D4NL-1CFG-B4, D4NL-1DFG-B4 D4DL-2DFG-B-HT ...

Related keywords