D4NL-1AFA-B Omron, D4NL-1AFA-B Datasheet - Page 5

SAFETY SWITCH

D4NL-1AFA-B

Manufacturer Part Number
D4NL-1AFA-B
Description
SAFETY SWITCH
Manufacturer
Omron
Datasheets

Specifications of D4NL-1AFA-B

Contact Voltage Ac Max
240V
Contact Voltage Dc Max
24V
Contact Current Ac Max
10A
Contact Current Dc Max
200mA
Switch Terminals
Screw
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
EN60747-5-1, IEC 947-5-1, EN1088,
Contact Configuration
SPST-NC / SPST-NO
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
AA-62
Guard Lock Safety-door Switch
The above values are initial values.
The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however,
they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability
for smaller loads may be reduced.
The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are
sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration,
do not use the D4NL in places where foreign material may enter through the key hole on the head, otherwise Switch damage or
malfunctioning may occur.
The durability is for an ambient temperature of 5 C to 35 C and an ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
If the ambient temperature is greater than 35 C, do not pass the 3-A, 250-VAC load through more than 2 circuits.
These figures are minimum requirements for safe operation.
This figure is based on the GS-ET-19 evaluation method.
This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the
actual load beforehand.
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA
Tel. 1/888/510-4357
Canada
D4NL
Tel. 1/866/986-6766
IP67 (EN60947-5-1)
(This applies for the Switch only. The degree of protection for the key hole is IP00.)
1,000,000 operations min.
500,000 operations min. for a resistive load of 3 A at 250 VAC (see note 5)
0.05 to 0.5 m/s
30 operations/minute max.
50/60 Hz
2 x 2 mm min
60 N min. (EN60947-5-1)
10 mm min. (EN60947-5-1)
1,300 N min.
100 M
Resistive load of 1 mA at 5 VDC (N-level reference value)
300 V (EN60947-5-1)
10 A (EN60947-5-1)
Between terminals of the same polarity
Between terminals of different polarities
Between other terminals and uncharged metallic parts
100 A (EN60947-5-1)
3 (EN60947-5-1)
Class II (double insulation)
25 m
10 to 55 Hz, 0.75-mm single amplitude
1,000 m/s
100 m/s
Operating: 10 C to 55 C with no icing
Operating: 95% max.
Approx. 370 g (D4NL-IAFA-B)
max. per contact (initial value)
2
min. (at 500 VDC)
min.
2
min.
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
2.5 kV
4 kV
6 kV