D4NL-1AFA-B Omron, D4NL-1AFA-B Datasheet - Page 6

SAFETY SWITCH

D4NL-1AFA-B

Manufacturer Part Number
D4NL-1AFA-B
Description
SAFETY SWITCH
Manufacturer
Omron
Datasheets

Specifications of D4NL-1AFA-B

Contact Voltage Ac Max
240V
Contact Voltage Dc Max
24V
Contact Current Ac Max
10A
Contact Current Dc Max
200mA
Switch Terminals
Screw
Svhc
No SVHC (15-Dec-2010)
Approval Bodies
EN60747-5-1, IEC 947-5-1, EN1088,
Contact Configuration
SPST-NC / SPST-NO
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Indicates conditions where the Key is inserted and the lock is applied. Terminals 12 and 41 are connected internally (as per GS-ET-19).
D4NL-@AF@-@
D4NL-@BF@-@
D4NL-@CF@-@
D4NL-@DF@-@
D4NL-@EF@-@
D4NL-@FF@-@
D4NL-@GF@-@
D4NL-@HF@-@
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA
Tel. 1/888/510-4357
1NC/1NO + 1NC/1NO
1NC/1NO + 2NC
2NC + 1NC/1NO
2NC + 2NC
2NC/1NO + 1NC/1NO
2NC/1NO + 2NC
3NC + 1NC/1NO
3NC + 2NC
Canada
Tel. 1/866/986-6766
11
33
11
33
11
31
11
31
11
21
33
11
21
33
11
21
31
11
21
31
Zb
Zb
Zb
Zb
Zb
Zb
Zb
Zb
12
34
12
34
12
32
12
32
12
22
34
12
22
34
12
22
32
12
22
32
41
53
41
51
41
53
41
51
41
53
41
51
41
53
41
51
Zb
Zb
Zb
Zb
Zb
Zb
Zb
Zb
42
42
42
42
42
42
42
42
54
52
54
52
54
52
54
52
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
11-42
11-42
21-22
21-22
33-34
33-34
53-54
53-54
11-42
21-22
33-34
51-52
11-42
33-34
53-54
11-42
33-34
51-52
11-42
31-32
53-54
11-42
11-42
31-32
51-52
51-52
11-42
21-22
31-32
53-54
11-42
21-22
31-32
51-52
Operation
Key insertion
completion position
Operation
Key insertion
completion
position
Operation
Key insertion
completion position
Operation
Key insertion
completion
position
Operation
Key insertion
completion position
Operation
Key insertion
completion position
Operation
Key insertion
completion position
Operation
Key insertion
completion position
Lock position
Lock position
Lock position
Lock position
Lock position
Lock position
Lock position
Lock position
Stroke
Stroke
Stroke
Stroke
Stroke
Stroke
Stroke
Stroke
Guard Lock Safety-door Switch
Extraction
completion
position
Extraction
completion
position
Extraction
completion
position
Extraction
completion
position
Extraction
completion
position
Extraction
completion
position
Extraction
completion
position
Extraction
completion
position
ON
ON
ON
ON
ON
ON
ON
ON
Only NC contacts 11-12
have an approved direct
opening mechanism.
The terminals 11-42, 33-
34, and 53-54 can be
used as unlike poles.
Only NC contacts 11-12
have an approved direct
opening mechanism.
The terminals 11-42, 33-
34, and 51-52 can be
used as unlike poles.
Only NC contacts 11-12
and 31-32 have an
approved direct opening
mechanism.
The terminals 11-42, 31-
32, and 53-54 can be
used as unlike poles.
Only NC contacts 11-12
and 31-32 have an ap-
proved direct opening
mechanism.
The terminals 11-42, 31-
32, and 51-52 can be
used as unlike poles.
Only NC contacts 11-12
and 21-22 have an ap-
proved direct opening
mechanism.
The terminals 11-42, 21-
22, 33-34, and 53-54 can
be used as unlike poles.
Only NC contacts 11-12
and 21-22 have an ap-
proved direct opening
mechanism.
The terminals 11-42, 21-
22, 33-34, and 51-52 can
be used as unlike poles.
Only NC contacts 11-12,
21-22, and 31-32 have an
approved direct opening
mechanism.
The terminals 11-42, 21-
22, 31-32, and 53-54 can
be used as unlike poles.
Only NC contacts 11-12,
21-22, and 31-32 have an
approved direct opening
mechanism.
The terminals 11-42, 21-
22, 31-32, and 51-52 can
be used as unlike poles.
D4NL