E5-024-C0400 EATON CUTLER HAMMER, E5-024-C0400 Datasheet - Page 4

Totalizing Counter

E5-024-C0400

Manufacturer Part Number
E5-024-C0400
Description
Totalizing Counter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of E5-024-C0400

No. Of Digits / Alpha
8
Digit Height
8mm
Counting Speed
30Hz
Operating Temperature Range
-10°C To +55°C
Meter Signal Input
Pulse
Character Size
0.31"
Ip/nema Rating
65
Panel Cutout Height
0.87"
Supply Voltage Range
10VAC To 260VAC / 10VDC To 260VDC
Digital display
Clamp
Front frame for screw mounting,
Panel cut-out 50 x 25 mm [1.97 x 0.98 in.]
Front frame for clamp mounting,
Panel cut-out 50 x 25 mm [1.97 x 0.98 in.]
Seal
Operating instructions
Use shielded wires for the counting and control inputs to
obtain the maximum EMC resistance.
Use shielded wires for the counting and control inputs to
obtain the maximum EMC resistance.
This device may only be used as a panel-mounted
device! Applications of this product may be found in
industrial processes and controls in the branch of the
manufacturing lines for the metal, wood, plastics, paper,
glass, textile, etc., processing industries. It must be
considered that the overvoltages at the terminals of the
device must be limited to the values of overvoltage
category II. Overvoltage category II is described in the
standard EN 61 010 Part 1.
This device shall only operate when it has been
correctly mounted in a panel. It may only be used in
accordance with the chapter “Main technical features”.
This device shall not be used:
– in areas with risks of explosion
– in the branches expressly quoted in the standard
If this device is used to monitor machines or a process
in which, in case of a failure of the device, there might
be risks of damaging the machine or causing accidents
to the operators, it is up to you to take appropriate
safety measures.
4
EN 61 010 T1.
Also take into account the fact that there may exist user
or country-specific safety regulations, which must also
be followed.
!
This product includes a
open it by force, do not throw it in the fire.
Avoid temperatures below -20°C [-4°F] and
above 70°C [158°F]!
Only use these counters
MN05401007E
battery. Do not

Related parts for E5-024-C0400