E53-C3N Omron, E53-C3N Datasheet - Page 17

no-image

E53-C3N

Manufacturer Part Number
E53-C3N
Description
OUTPUT UNIT 4-20MA OUTPUT
Manufacturer
Omron
Datasheet

Specifications of E53-C3N

Accessory Type
Output Unit - Linear 4-20 MA
Current Rating
20mA
Svhc
No SVHC (15-Dec-2010)
No. Of Analogue Outputs
1
For Use With
E5EN-H And E5AN-H Controllers
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operation
E5EN-H / E5AN-H
✽1. You can return to the operation level by executing a software reset.
✽2. It is not possible to move to other levels from the calibration level by operating the keys on the front panel.
✽3. From the manual control level, key operations can be used to move to the operation level only.
✽4. When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN-H/E5EN-H).
✽5. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN-H/E5EN-H)
Error Displays (Troubleshooting)
When an error occurs, the No.1 display shows the error code. Take necessary measure according to the error code, referring the table below.
Note: If the input value exceeds the display limit (-19999 to 32400), though it is within the control range,
✽ These errors are displayed only when the PV/SP is displayed. Errors are not displayed for other displays.
s.err
e333
e111
Manual
mode
No.1 display
It can be done only by first turning OFF the power.
and
For details on the control range, refer to the E5CN-H/E5AN-H/E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157).
(E333)
(E111)
(S. Err)
Manual
Control Level
Start in manual mode.
Press the O Key or the
PF Key for at least 1 s. ✽4
✽3
above 32400. Under these conditions, control output and alarm output will operate normally.
Input error
A/D
converter
error
Memory
error
Meaning
a-m
Press the O Key
for at least 3 s while
a-m is displayed.
(a-m will flash after
1st second.)
Control stops.
Start in automatic mode.
Press the PF Key
for at least 1 s.
Check the wiring of inputs for miswiring, disconnections, and short-circuits and check the
input type.
Turn the power OFF then back ON again. If the display remains the same, the controller must
be repaired. If the display is restored to normal, then a probable cause can be external noise
affecting the control system. Check for external noise.
Turn the power OFF then back ON again. If the display remains the same, the controller must
be repaired. If the display is restored to normal, then a probable cause can be external noise
affecting the control system. Check for external noise.
Press the O Key
for at least 1 s.
Press the O Key
for at least 1 s.
✽4
✽1
Advanced Digital Temperature Controller
Operation
Level
Power ON
Initial Setting
Level
Advanced Function
Setting Level
PF Key
✽5
PID Setting
Level
Calibration Level
Press the
O Key less than 1 s.
Press the
O Key less than 1 s.
Monitor/Setting
Item Level
Input password.
Action
Input password while
amov is displayed.
(Set value −169)
Press the
O Key for less than 1 s.
c
Press the
O Key less
than 1 s.
25.0
100.0
✽2
Press the O Key for at
least 3 s. (Display will flash
after 1st second.)
Communica-
tions Setting
Level
Bank Setting
Level
Adjustment
Level
PF Key
Press the
O Key less
than 1 s.
✽5
Control in progress
Control stopped
Not displayed for some models
Level change
E5AN-H/E5EN-H
Press
the O +
M Keys
for at
least 3 s.
(Display
will flash
after 1st
second.)
Note: The time taken to
Control output
will be displayed under -19999
c
25.0
move to the protect
level can be adjusted
by changing the
“Move to protect level
time” setting.
Protect Level
100.0
OFF
OFF
OFF
Status at error
Operates as above
Press the O+
M Keys for at
least 1 s.
the upper limit.
Alarm output
OFF
OFF
17