E53-C3N Omron, E53-C3N Datasheet - Page 19

no-image

E53-C3N

Manufacturer Part Number
E53-C3N
Description
OUTPUT UNIT 4-20MA OUTPUT
Manufacturer
Omron
Datasheet

Specifications of E53-C3N

Accessory Type
Output Unit - Linear 4-20 MA
Current Rating
20mA
Svhc
No SVHC (15-Dec-2010)
No. Of Analogue Outputs
1
For Use With
E5EN-H And E5AN-H Controllers
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
c
c
c
l.adj
irda
spmd
lcr1
lcr2
insh
cmwt
insl
hb1
oc1
hs1
M
ct1
ct2
hb2
oc2
hs2
ins
50.0
50.0
50.0
50.0
0.00
0.00
0.00
off
off
off
lsp
at
M
M
M
M
0.0
M
0.0
M
M
0.0
M
0.0
M
M
0.0
M
M
0.0
M
M
M
M
M
Adjustment Level
Display
Displayed only
once when
entering
adjustment level.
AT Execute/Cancel
Communications
Writing
Infrared Communications Use
SP Mode
Heater Current 1
Value Monitor
Heater Overcurrent
Detection 1
Upper Limit
Temperature
Input Shift Value
Heater Burnout
Detection 1
Leakage Current 1
Monitor
Temperature Input Shift
Lower Limit
Temperature
Input Shift Value
Heater Current 2
Value Monitor
Heater Burnout
Detection 2
Heater Overcurrent
Detection 2
HS Alarm 1
Leakage Current 2
Monitor
HS Alarm 2
1-point shift
2-point shift
Adjustment Level
Set either
of these
param-
eters.
✽1. When the PF Setting parameter is set to A-M for a Controller with a PF Key (E5AN-H/E5EN-H).
✽2. When the PF Setting parameter is set to PFDP for a Controller with a PF Key (E5AN-H/E5EN-H).
c
Advanced Digital Temperature Controller
Press the O Key less than 1 s.
of-r
wt-b
mv-s
mv-e
ol-h
oc-h
sqrp
c-sc
c-db
chys
soak
sprt
ol-l
233.0
105.0
hys
orl
40.0
50.0
-5.0
1.00
off
M
M
M
M
M
M
M
M
M
off
M
M
M
M
M
M
db
0.0
M
M
M
8.0
0.0
0.0
M
0.0
0.0
1.0
1.0
2.0
0.8
Press the PF Key
for at least 1 s.
p
d
i
1
Cooling Coefficient
Proportional Band
Dead Band
Manual Reset Value
Clear the offset during
stabilization of P or PD
control.
Hysteresis (Heating)
Integral Time
Derivative Time
Hysteresis (Cooling)
Soak Time
SP Ramp Set Value
Open/Close Hysteresis
Extraction of Square
Root
Low-cut Point
Wait Band
MV at Stop
MV at PV Error
MV Upper Limit
MV Lower Limit
Position Proportional
Dead Band
MV Change Rate Limit
Hysteresis settings
Heating/cooling
PID settings
✽1
Starting in manual mode.
Press
the O
Key for
at least
3 s.
PV/MV
c
Manual Control Level
25.0
100.0
Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item 1 to
PF Key ✽2
25.0
c
c
c
Monitor/Setting Item Level
sp-m
lcr1
lcr2
sktr
0.0
bank
prst
5 parameters (advanced function setting level).
25.0
25.0
ct1
a-m
rsp
ct2
PID
Control
only
rset
M
M
M
M
M
M
M
M
M
M
M
M
Monitor/Setting
Item Display 1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
Process Value/
Set Point
Auto/Manual Switch
PID control only.
Added when
auto/manual select
addition is ON.
Soak Time Remain
Process Value
Added when Additional
PV display is ON.
Set Point During
SP Ramp
Heater Current 1 Value
Monitor
Heater Current 2 Value
Monitor
Leakage Current 1
Monitor
Leakage Current 2
Monitor
Program Start
Bank No.
Remote SP Monitor
Monitor/Setting
Item Display 4
Press the O
Key or the PF
Key for at least
1 s. ✽1
Operation Level
Power ON
PF
PF
E5AN-H/E5EN-H
c
c
c
c
c
c
c
Starting in
automatic
mode.
al-1
al-3
al1h
al-2
al2h
al3h
Monitor/Setting
Item Display 2
al1l
al2l
al3l
r-s
v-m
c-o
run
M
M
M
M
M
M
M
M
M
M
M
M
M
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
o
Monitor/Setting
Item Display 5
RUN/STOP
MV Monitor (Heating)
Alarm Value 1
Alarm Value
Upper Limit 1
Alarm Value
Lower Limit 1
Alarm Value 2
Alarm Value 3
Alarm Value
Upper Limit 3
Alarm Value
Lower Limit 3
MV Monitor (Cooling)
Alarm Value
Upper Limit 2
Alarm Value
Lower Limit 2
Valve Opening
Monitor
(E5AN-H/E5EN-H only)
PF Key
PF
✽2
Monitor/Setting
Item Display 3
Press the O
and M Keys for
at least 3 s.
Press the O
and M Keys for
at least 1 s.
PF
19

Related parts for E53-C3N