no-image

B200

Manufacturer Part Number
B200
Description
Solid State Relays, Accessories
Manufacturer
OPTO 22
Type
Processr
Datasheets

Specifications of B200

Accessory Type
16 Position Mounting Board
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Supply Voltage
5V
Communication
Twisted Pair with Shield
Data Rate
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 76800, and 115200 Baud
Interface
RS-485 Twisted Pair with Shield, 2-Wire or 4-Wire
Led Position
RUN (Power ON), RCV (Receive), XMT (Transmit) and IRQ (Interrupt)
Mounting Type
Rack
Number Of Channels
16
Power Source
5
Special Features
Serial Communications
Temperature, Operating
0 to +70 °C
For Use With
Optomux Protocol
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
B20025
Manufacturer:
EPCOS/爱普科斯
Quantity:
20 000
Part Number:
B200NF03
Manufacturer:
ST
0
Part Number:
B200NF03-1
Manufacturer:
ST
0
Part Number:
B200NF04
Manufacturer:
ST
0
Part Number:
B200NF04-1
Manufacturer:
ST
0
Part Number:
B200NF04L
Manufacturer:
ST
0
Part Number:
B200NF04L
Manufacturer:
ST
Quantity:
20 000
DATA SHEET
Form 730-050728
Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Phone: (951) 695-3000 • (800) 321-OPTO • Fax: (951) 695-3095 • www.opto22.com
Specifications
MISTIC Command Set - Analog Functions
Analog Setup/System Commands
IDENTIFY TYPE
POWER-UP CLEAR
REPEAT LAST RESPONSE
RESET
RESET ALL PARAMETERS TO DEFAULT
SET COMM LINK WATCHDOG AND DELAY
SET COMM LINK WATCHDOG TIME-OUT DATA
SET RESPONSE DELAY
SET SYSTEM OPTIONS
Analog I/O Configuration Commands
CALCULATE AND SET ADC MODULE OFFSET
CALCULATE AND SET ADC MODULE GAIN
READ MODULE CONFIGURATION
SET ADC MODULE OFFSET
SET ADC MODULE GAIN
SET AVERAGING SAMPLE WEIGHT
SET CHANNEL CONFIGURATION
SET ENGINEERING UNIT SCALING PARAMETERS
SET I/O CONFIGURATION - GROUP
SET TOTALIZATION SAMPLE WEIGHT
SET TPO RESOLUTION
STORE SYSTEM CONFIGURATION
Analog Read/Write/Output Commands
RAMP DAC OUTPUT TO ENDPOINT
READ AND CLEAR I/O MODULE DATA
READ AND CLEAR I/O MODULE DATA - GROUP
READ I/O MODULE MAGNITUDE
READ I/O MODULE MAGNITUDE - GROUP
SET DAC MODULE MAGNITUDE, ENG. UNITS
SET DAC MODULE MAGNITUDE, ENG. UNITS - GROUP
SET DAC MODULE MAGNITUDE, COUNTS
SET DAC MODULE MAGNITUDE, COUNTS - GROUP
Inside Sales: (800) 321-OPTO • Product Support: (800)TEK-OPTO • (951) 695-3080 • Fax: (951) 695-3017 • E-mail: sales@opto22.com
1. For detailed information about Mistic Command Set, refer to Mistic Protocol
2. For detailed information about Optomux Command Set, refer to Optomux Protocol
User’s Guide (Form #270) or Misticware
Guide (Form #1572).
User’s Guide (Form #522).
Analog Event/Reaction Commands
CLEAR EVENT/REACTION TABLE
CLEAR EVENT TABLE ENTRY
CLEAR INTERRUPT
ENABLE/DISABLE EVENT ENTRY - GROUP
ENABLE/DISABLE EVENT TABLE ENTRY
READ AND CLEAR EVENT LATCHES
READ EVENT DATA HOLDING BUFFER
READ EVENT ENTRY ENABLE/DISABLE STATUS
READ EVENT LATCHES
READ AND OPTIONALLY CLEAR EVENT LATCH
READ EVENT TABLE ENTRY
SET EVENT INTERRUPT STATUS
SET EVENT ON COMM LINK WATCHDOG TIME-OUT
SET EVENT ON I/O >= SETPOINT
SET EVENT ON I/O <= SETPOINT
SET EVENT REACTION COMMAND
Analog PID Loop Commands
INITIALIZE PID LOOP
READ ALL PID LOOP PARAMETERS
READ PID LOOP PARAMETER
SET PID LOOP CONTROL OPTIONS
SET PID LOOP DERIVATIVE RATE
SET PID LOOP GAIN
SET PID LOOP INTEGRAL RESET RATE
SET PID LOOP MIN-MAX OUTPUT LIMITS
SET PID LOOP MIN-MAX SETPOINT LIMITS
SET PID LOOP PROCESS VARIABLE
SET PID LOOP SETPOINT
16-CHANNEL ANALOG
CLASSIC/MISTIC
BRAINS
page 3/10