K3HB-SSD 100/240VAC Omron, K3HB-SSD 100/240VAC Datasheet

METER, SENSOR, LINEAR, 100/240AC

K3HB-SSD 100/240VAC

Manufacturer Part Number
K3HB-SSD 100/240VAC
Description
METER, SENSOR, LINEAR, 100/240AC
Manufacturer
Omron
Datasheet

Specifications of K3HB-SSD 100/240VAC

Power Consumption
18VA
Svhc
No SVHC (15-Dec-2010)
External Depth
95mm
External Length / Height
48mm
Ip/nema Rating
IP20
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Supply
RoHS Compliant
Approval Bodies
CE, CRUus, UL
Current Consumption
50mA
Rohs Compliant
Yes
For Use With
High-speed,
Digital Indicators
K3HB
Series
Distinct by Design,
Distinguished in Performance
K3HB-H
K3HB-S
K3HB-X
K3HB-V

Related parts for K3HB-SSD 100/240VAC

K3HB-SSD 100/240VAC Summary of contents

Page 1

... Digital Indicators K3HB Series Distinct by Design, Distinguished in Performance K3HB-H K3HB-S K3HB-X K3HB-V ...

Page 2

... In addition to im- proved response times for judgement output and transfer output, average processing can be used to increase the sta- bility of measurements. Note: The K3HB-S Linear Sensor Indicator features high-speed re- sponse of 2,000 times/second. Sampling at 15 times/second Sampling at 50 times/second ...

Page 3

... Indicates Temperature Measurements • K3HB-HTA Platinum-resistance thermometer (Pt100: 2 ranges) Thermocouple (K: 2 ranges ranges ■ K3HB-S Linear Sensor Indicator (page 16) Measures and Discriminates Results at High Speed with High Accuracy • K3HB-SSD 0.000 to 20.000 mA, 4.000 to 20.000 mA, 0.000 to 5.000 V, 1.000 to 5.000 V, ±5.000 V, ±10.000 V, two-channel input ...

Page 4

... K32-DICN: Special Cable (for event inputs, with 8-pin connector) K32-BCD: Special BCD Output Cable K3HB-X 4 Process Indicator Base Units with Optional Boards K3HB-X@-@@@ Sensor Power Supply/Output Type Codes None: None CPA: Relay output (PASS: SPDT) + Sensor power supply (12 VDC +/−10%, 80 mA) (See note 1.) L1A: Linear current output (DC0(4) − ...

Page 5

... DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommend- ed. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. Load: 500 Ω max, Resolution: Approx. 10,000, Output error: ±0.5% FS Load Ω ...

Page 6

... Radiated Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity Conducted Disturbance Immunity Voltage Dips and Interruptions Immunity K3HB-X 6 Process Indicator ± 1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 µ s/100 ns) ± ...

Page 7

... MΩ − E6 COM 4. The K3HB-XVA@@ complies with UL standards when the applied input voltage is within the range 0 to 150 VAC. If the input voltage is higher than 150 VAC, install an external transformer or take other measures to drop the voltage to 150 VAC or lower. Measurement range Input impedance 10 M Ω ...

Page 8

... K32-DICN: Special Cable (for event inputs, with 8-pin connector) K32-BCD: Special BCD Output Cable K3HB-V 8 Weighing Indicator Base Units with Optional Boards K3HB-V@-@@@ Sensor Power Supply/Output Type Codes None: None CPB: Relay output (PASS: SPDT) + Sensor power supply (10 VDC +/ − 5%, 100 mA) (See note 1.) L1B: Linear current output (DC0(4) − ...

Page 9

... DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommend- ed. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. 100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC 85% to 110% of the rated power supply voltage, DeviceNet power supply VDC 100 to 240 max ...

Page 10

... Radiated Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity Conducted Disturbance Immunity Voltage Dips and Interruptions Immunity K3HB-V 10 Weighing Indicator ± 1,500 V at power supply terminals in normal or common mode (waveform with 1-ns rising edge and pulse width of 1 µ s/100 ns) ± ...

Page 11

... E6 E5 199.99 100.00 19.999 0.000 − 100.00 − 199.99 ■ Scaling Example Using Range A Indicated on the K3HB 49N in the load cell specifications (rated load 49N, recommended applied voltage 10 V, rated output 2 mV/V) (See note.) Display value + −OUT Load cell −IN Note: 2 mV/V indicates a load cell output for 1 V applied volt- age for the rated load (when using a load of 1 N). When the ap- plied voltage the load cell output × ...

Page 12

... DRT: 4. Event input Type Codes None K3HB Relay output (PASS: SPDT) + Sensor power supply (12 VDC +/−10%, 80 mA) (See note 1.) Linear current output (DC0(4) − 20 mA) + Sensor power supply (12 VDC +/−10%, 80 mA) (See note 2.) Linear voltage output (DC0(1) − Sensor power supply (12 VDC +/− ...

Page 13

... DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Ca- bles. ...

Page 14

... EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz) EN61000-4- (power line (I/O signal line) EN61000-4- with line (power line with ground (power line) EN61000-4- (0. MHz) EN61000-4-11: 0.5 cycle, 0 ° /180 °, 100% (rated voltage) K3HB sweeps of 5 min each and Z directions ...

Page 15

... 1700.0 1700.0 1800.0 1300.0 850.0 400.0 0.0 0.0 − 100.0 − 200.0 − 200.0 8-l 9-u 10-n 11-r 12-s 0.1 ° C K3HB-H Temperature Indicator B W (W/Re 5-26) 2300.0 100.0 0.0 13-b 14-w 15 ...

Page 16

... NPN open collector 2: 8 points (10-pin MIL connector) NPN open collector 3: 5 points (M3 terminal blocks) PNP open collector 4: 8 points (10-pin MIL connector) PNP open collector K3HB (12 VDC +/ − 10%, 80 mA) (See note 1.) (12 VDC +/ − 10%, 80 mA) (See note 2.) (12 VDC +/ − ...

Page 17

... DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommend- ed. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. 24 VAC/VDC, DeviceNet power supply: 24 VDC DeviceNet power supply VDC Load: 500 Ω ...

Page 18

... EN61000-4- (0. MHz) EN61000-4-11: 0.5 cycle, 0 ° /180 °, 100% (rated voltage) Indication range − 2.000 to 22.000 mA 2.000 to 22.000 mA − 0.500 to 5.500 mA 0.500 to 5.500 V ± 5.500 V ± 11.000 V K3HB-S Input Accuracy Maximum (at 23 ± 5 ° C) impedance absolute rated 120 Ω max. One input: ± ...

Page 19

... The range shown in dark shading indicates the factory setting. Sampling and Comparative Output Response Times The K3HB-S sampling and comparative output response times depend on the calculation methods, timing hold type, and, for simple averaging, the averaging times. Refer to the following description for details. ...

Page 20

... Stop bit length 2 bits or 1 bit Error detection Vertical parity and FCS Parity check Odd, even Note: For details on serial and DeviceNet communications, refer to the Digital Indicator K3HB Communications User's Manual (Cat.No. N129). K3HB-X/-V/-H/-S 20 Digital Indicators BANK4 Transistor Output ...

Page 21

... Transistor circuit output Micro- computer Drive X Relay output circuit Drive DeviceNet DeviceNet circuit circuit Communi- Drive cations Communications circuit driver COM V O DC-DC Converter (isolated) Digital Indicators Drop line length Total drop line (max.) (max.) length (max 156 m K3HB-X/-V/-H/-S 21 ...

Page 22

... Turns ON when the tare zero function is T-ZR executed. Turns OFF not executed or is cleared. Turns ON when the forced-zero function is Zero executed. Turns OFF not executed or is cleared. (Excluding the K3HB-H.) Turns ON/OFF when hold input turns Hold ON/OFF. MAX/MIN Key LEVEL Key Used to switch the Used to switch level ...

Page 23

... VDC Refer to the following User's Manual for application precautions and other information required when using the Digital Indicator: K3HB-S/-X/-V/-H Digital Indicator User's Manual (Cat. No. N128) The manual can be downloaded from the following site in PDF format: OMRON Industrial Web http://www.fa.omron.co.jp Continuous Data Output REQ ...

Page 24

... Always use a EN/IEC-compliant power supply with reinforced insulation or double insulation for the DeviceNet power supply. • The product must be used indoors for the above applicable standards to apply. • The K3HB-XVA@@ complies with UL standards when the applied input voltage is within the range 0 to 150 VAC ...

Page 25

... XG4M-1030 (OMRON) • Special Cable (Sold separately) K32-DICN (OMRON) (XG4M-1030 with 3 m cable) BCD Output Cable Model K32-BCD K3HB end 38 mm Cover: HDR-E50LPA5 (manufactured by Honda Tsushin Co., Ltd) Connector: HDR-E50MAG1 (manufactured by Honda Tsushin Co., Ltd) Note: The BCD Output Cable has a D-sub plug. Cover: 17JE-37H-1A (manufactured by DDK); Connector: equivalent to 17JE-23370-02 (D1) (manufactured by DDK) ...

Page 26

... Shifts the temperature input value Supported Models The models that support the functions shown here are indi- cated by symbols as follows: X K3HB-X V K3HB K3HB-H S K3HB-S K−A Input Sampling hold value ON OFF Input Peak-to-peak value (b1−a1) b1 'b2 a1 'a2 ON OFF ...

Page 27

... For example, if the setting is 2, the small- est digit will only take the values and if the setting will only take the values the setting is 10, it will only take the value Input Red 110.01 H 110.00 Digital Indicators K3HB-X/-V/-H/-S 27 ...

Page 28

... Output PASS Output L Output LL Output Logic Reverses the output operation of comparative outputs for compara- tive results. ■ Dimensions K3HB-X/-V/-H/-S 28 Digital Indicators Hysteresis Prevents comparative output chattering when the measurement value fluctuates slightly near the set value. Example: Comparative Output Pattern (Standard Output) ...

Page 29

... Insert the adapter into the grooves on the left and right sides of the rear case and push until it reaches the panel and is fixed in place. Adapter ■ LCD Field of Vision The K3HB is designed to have the best visibility at the angles shown in the following diagram. 10° 30° ■ Waterproof Packing The waterproof packing ensures a level of waterproofing that con- forms to NEMA 4X ...

Page 30

... Doing so may occasionally result in minor or moderate injury due to electric shock. Do not use the equipment for measurements within Measurement Categories III and IV for K3HB-X and II, III, and IV for K3HB-S, K3HB-V, and K3HB-H (according to IEC61010-1). Doing so may occasionally cause unexpected operation, resulting in minor or moderate injury, or damage to the equipment ...

Page 31

... If a noise filter is used for the power supply, check the voltage and current, and install the noise filter as close to the product as pos- sible. 5. Reception interference may occur if the product is used close to a radio, television, or wireless. Digital Indicator Surge suppressor Digital Indicator Digital Indicators K3HB-X/-V/-H/-S 31 ...

Page 32

... Warranty and Limitations of Liability ■ WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE ...

Related keywords