K3HB-SSD 100/240VAC Omron, K3HB-SSD 100/240VAC Datasheet - Page 22

METER, SENSOR, LINEAR, 100/240AC

K3HB-SSD 100/240VAC

Manufacturer Part Number
K3HB-SSD 100/240VAC
Description
METER, SENSOR, LINEAR, 100/240AC
Manufacturer
Omron
Datasheet

Specifications of K3HB-SSD 100/240VAC

Power Consumption
18VA
Svhc
No SVHC (15-Dec-2010)
External Depth
95mm
External Length / Height
48mm
Ip/nema Rating
IP20
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Supply
RoHS Compliant
Approval Bodies
CE, CRUus, UL
Current Consumption
50mA
Rohs Compliant
Yes
For Use With
High-speed,
■ Power Supply Derating Curve for Sensor (Reference Value)
Note: 1. The above values are for standard mounting. The derating curve differs depending on the mounting conditions.
■ Component Names and Functions
22
With 12 V
Max. current (mA)
140
120
100
80
60
40
20
0
−20
Turns ON when the maximum value or minimum value is
displayed in the RUN level.
Max/Min status indicator
2. Do not use the Sensor outside of the derating area (i.e., do not use it in the area labeled A in the above graphics). Doing so may occa-
Display the status of comparative outputs.
In RUN level, displays the bank if the bank function is
ON. (Turns OFF if the bank function is OFF.)
In other levels, displays the current level.
Used to switch the
display between the
PV, maximum value,
and minimum value and
to reset the maximum
and minimum values.
sionally cause deterioration or damage to internal components.
Display
T-ZR
Zero
Hold
Comparative output
−10
Level/bank display
status indicators
MAX/MIN Key
Status indicators
Digital Indicators
Turns ON when the tare zero function is
executed. Turns OFF if it is not executed or
is cleared.
Turns ON when the forced-zero function is
executed. Turns OFF if it is not executed or
is cleared. (Excluding the K3HB-H.)
Turns ON/OFF when hold input turns
ON/OFF.
0
10
20
Function
Ambient temperature (°C)
30
Used to switch level.
40
K3HB-X/-V/-H/-S
1
LEVEL Key
50
60
Max. current (mA)
With 10 V
MAX/MIN
HH
LL
H
P
L
140
120
100
Max
L
Min
T-ZR
Zero
80
60
40
20
Used to switch the
parameters displayed.
0
−20
CMW
Hold
LEVEL
MODE Key
−10
TG
T
MODE
HH
LL
0
H
L
10
SHIFT
20
UP
Ambient temperature (°C)
30
Used to change
parameter settings.
When changing a set
value, this key is used
to move along the
digits.
40
SHIFT Key
1
50
Displays PVs, maximum values,
minimum values, parameter
names, and error names.
Displays the position of the PV with
respect to a desired scale.
Displays SV and monitor values.
60
HH, H,
L, LL
SV display status indicators
Display
TG
T
Position meter
PV display
SV display
In RUN level, turn ON when the
comparative set values HH, H, L, and
LL are displayed.
Turns ON when the timing signal turns
ON. Otherwise OFF.
Turns ON when parameters for which
teaching can be performed are
displayed.
When changing a set value,
this key is used to change
the actual value.
When a measurement value
is displayed, this key is
used to execute or clear the
forced-zero function or to
execute teaching.
Function
UP Key

Related parts for K3HB-SSD 100/240VAC