10054542-001LF FCI, 10054542-001LF Datasheet - Page 6

no-image

10054542-001LF

Manufacturer Part Number
10054542-001LF
Description
CONN RECEPT SAS 22POS VERT PCB
Manufacturer
FCI
Datasheet

Specifications of 10054542-001LF

Connector Style
Receptacle
Connector Type
SAS
Number Of Positions
22
Mounting Type
Through Hole
Termination
Solder
Contact Finish
Gold
Contact Finish Thickness
3µin (0.08µm)
Product
SAS Connectors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
609-1549
7.0
NUMBER
TITLE
Copyright
Form E-3334
Rev F
7.2
7.3
7.4
ENVIRONMENTAL CONDITIONS
GS-12-239
After exposure to the following environmental conditions in accordance with “Table 1 – Qualification Test Matrix”,
the product shall show no physical damage and shall meet the electrical and mechanical requirements in sections
6 and 7. Unless specified otherwise the products shall be mated during exposure.
7.1
FCI
Perform in accordance with EIA 364-32C. The following details shall apply:
a. Number of cycles: 5
b. Temperature range: -55 to + 85
c. Time at each temperature: 30 minutes minimum
d. Transfer time: 30 seconds maximum
Mated samples are to be exposed to cyclical humidity and temperature in accordance with EIA 364-31B.
A cycle consists of the following steps.
a. 2 hour ramp from 25°C at 80%-98% RH to 65°C at 90%-98% RH
b. 4 hour dwell at 65°C at 90%-98% RH
c. 2 hour ramp down to 25°C at 80%-98% RH
d. 2 hour dwell at 25°C at 80%-98% RH
Perform in accordance with EIA 364-17B. Headers and receptacles shall remain mated without any
a. Temperature: 85°C
b. Duration: 500 hours
Expose samples to gas mixture per Telcordia GR-1217-CORE, November 1995, Section 9.1.3 as follows:
a. Temperature: 30°C
b. Relative humidity: 70%
c. Mandatory readings after the 10
d. Gas compositions, per Central Office requirements:
Case 1: Backpanel and Orthogonal Applications
Un-mated backpanel connectors are to be exposed to gas mixture for 10 days, then mated and exposed
Case 2: Coplanar Applications
Each connector gender is to be exposed to gas mixture in the unmated condition for 10 days, then mated
Thermal Shock:
Cyclical Humidity and Temperature:
Samples are to be subjected to 50 cycles of 10-hour duration for a total of 500 hours.
Temperature Life:
electrical load. The following details shall apply:
Industrial Mixed Flowing Gas (Class IIA, 4-gas):
for an additional 10 days.
to an unexposed connector for a 10 day additional gas exposure and the remainder of the test.
AirMax VS
Gas Type
TYPE
®
NO
H
SO
Cl
Connector System, press-fit products
2
S
2
2
2
PRODUCT SPECIFICATION
Gas Concentration
200 ppb
100 ppb
10 ppb
10 ppb
o
th
C
and 20
PDM: Rev:F
th
days
STATUS:
PAGE
AUTHORIZED BY
STATUS
Tan Chen Hong
Released
6 of 11
UNRESTRICTED
Printed: Oct 04, 2008
REVISION
DATE
GS-01-001
30 Sep 08
F
.