AMPLIFIER,[NAVI] DIGITAL, RED, NPN, 12-24VDC, QD

FX-301

Manufacturer Part Number
FX-301
Description
AMPLIFIER,[NAVI] DIGITAL, RED, NPN, 12-24VDC, QD
Manufacturer
PANASONIC EW
Datasheet

Specifications of FX-301

Rohs Compliant
YES
Features
The most compact size and yet the highest level of perfor-
mance in their class. These sensors save space.
A high resolution of 4μm (at an average 64 cycles) allows high-
precision positioning and size judgment.
The sensors are sensitive to min-
ute differences in light intensity so
that they can judge even the opac-
ity of glass and turbidity of liquids.
In addition, the amount of light re-
ceived can be displayed as a per-
centage to allow you to determine
permea tion rates.
Technical Specifications
Sensor heads
Notes:
Type
Sensing range
Sensing width
Min. sensing
object
Repeatability
(during the state
in which light is
half blocked)
Linear output
resolution
Ambient
temperature
Small sensor head
Resolution of 4μm
High-precision measurement even of
minute differences in light intensity
IEC / JIS
standards
FDA
standards
conforming
type
2) With an average sampling rate of 64 times.
HL-T10MF is FDA standards conforming type.
∅8μm opaque
4μm (Note 2)
4μm (Note 2)
0 to 500mm
Red semiconductor laser, Class 2 (FDA) [modulated, max. output 0.35mW
Beam diameter ∅1mm type
∅1mm
object
(HL-T1001A(F): 0.2 mW), emission peak wavelength: 650nm]
(HL-T1001A(F): 0.2mW), emission peak wavelength: 650nm]
HL-T1001A(F)
500 to 2000mm
∅50μm opaque
∅1 to ∅2.5mm
object
0 to +50°C
M
Sensing width
opaque object
HL-T1005A(F)
∅0.05mm
5mm
EASUREMENT
5mm
4μm (Note 2)
4μm (Note 2)
500mm
∅0.1mm opaque
Sensing width
HL-T1010A(F)
10mm type
10mm
object
04/2011
A high-functionality intelligent
controller
The calculation unit (optional) just needs to be connected be-
tween the two controllers to enable calculations (addition and
subtraction) to be carried out for two sensors. No digital panel
controller is needed.
FDA standards conforming types, most suitable for equipment used in
the USA, are now available
Controllers
Type
Model no.
Supply voltage
Measuring cycle
Linear output
Temperature
characteristics
Settable average
sampling rate
Judgment output
(HIGH, PASS, LOW)
Ambient temperature
Dimensions (mm)
Calculations for 2 sensors are possible
FDA standards conforming types are
available
S
ENSORS
HL-T1
Current / voltage output switchable
During current output: 4 to 20mA/F.S., max. load resistance 300Ω
During voltage output: 54V/F.S., output impedance 100Ω
(In the monitor focus function, it can also be set at 55V,
0 to 5V, etc.)
NPN open-collector transistor
1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1024 / 2048 / 4096
NPN output
HL-AC1
Calculation unit
HL-AC1-CL
W30×H34.3×D64.3
12 to 24VDC ±10%
±0.2% F.S./°C
0 to +50°C
150μs
PNP open-collector transistor
PNP output
HL-AC1P
135