CDTL400 Cooper/Bussmann, CDTL400 Datasheet

no-image

CDTL400

Manufacturer Part Number
CDTL400
Description
Terminal Lug Kit #2-600kcmil Wire
Manufacturer
Cooper/Bussmann
Datasheet

Specifications of CDTL400

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Disconnect Switches
Productivity
Through
Protection

Related parts for CDTL400

CDTL400 Summary of contents

Page 1

Productivity Through Protection ™ Disconnect Switches ...

Page 2

Table of Contents Disconnect Switches Compact, Heavy-Duty Table of Contents Fusible Disconnect Switches .....................................Page 2 Non-Fusible Disconnect Switches ...........................Page 29 Enclosed Fusible Disconnect Switches ..................Page 71 Enclosed Non-Fusible Disconnect Switches ..........Page 75 Index by Part Number ............................................... Page 86 ...

Page 3

CFD30AJ3 CFD60J3 Catalog number 3 pole CFD30ACC3 General purpose amp rating Approvals 2 pole N/A 3 pole UL98 & IEC 4 pole UL98 & IEC Technical ratings (UL, cULus) Max operating voltage V 600 Max horsepower rating ...

Page 4

Fusible Disconnect Switches Base & DIN Rail Mounted UL Fuse Class J, CC For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 30 Amp switches, 600V UL general purpose amp rating 3 pole ...

Page 5

For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft Pistol handles — for use with shafts NEMA 1,3R,12 1,3R,12 1,3R,12 1,3R,12 BDH56, BDH58 1,3R,4,4X,12 1,3R,4,4X,12 1,3R,12 1,3R,12 BDH57, BDH59 Shafts — for use with ...

Page 6

Accessories for 30A Fusible Disconnect Switches Auxiliary contacts Form C 1 N.O. & 1 N.C. (2 maximum) (6 maximum) CFD30AJ3 with auxiliaries Mounting base Mounting base Terminal pole Detachable neutral mounts CFDZX171 on side of switch or DIN rail DIN ...

Page 7

Conversion mechanisms • Switches are not included BDZW6 pole — BDZW5 6 (8) pole mechanism allows two switches, controlled by one handle, to open or close simultaneously. Equipment required for a complete installation: • One conversion mechanism ...

Page 8

Fusible Disconnect Switches UL Fuse Class J For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit 60 – 100 Amp switches, 600V UL general purpose amp ...

Page 9

Terminal lug kit BDTL24 Auxiliary contacts CDAUX10, CDAUX01K Replacement fuse clip CFC60J CFCVR100 Replacement fuse covers Terminal shroud CFTS100 Terminal poles CFZ1 DIN rail NDNA100 35mm Aluminum DIN Rail 35mm Aluminum DIN Rail “T” type fuse adapter kit BDTA1 8 ...

Page 10

Accessories for 60A – 100A Fusible Disconnect Switches Locking accessories Cam attachment for Kirk Key, Castell, Lowe & Fletcher and Ronis interlock. Cam attachment for adapting to the interlock system. The interlock is not included. CDETL-ZW16 Shaft extension coupler Joins ...

Page 11

For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit 200 Amp Switches, 600V UL general purpose amp rating 3 pole 200 BDH58,60 4 pole 200 Pistol handles - NEMA type ...

Page 12

Accessories for 200A Fusible Disconnect Switches Terminal Lug Kits For use on: CFD200JO3 #4-300kcmil CFD200J04 (6) 14-6 AWG CDTL200 Auxiliary Contacts Description 1 N.O. 1 N.C. Module for auxililary contacts CDAUX10, CDAUX01K Screw mounting to the left side of the ...

Page 13

Shaft extension coupler Joins two shafts together for applications where extended length is required BDZX167, BDZW95 Shaft adapter Adapts one end of a 6mm shaft to 12mm. Use with shaft extension coupler CDZK19 (X=6mm) Conversion mechanisms BDZW2 ...

Page 14

Fusible Disconnect Switches UL Fuse Class For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit 400 – 800 Amp switches, 600V UL general purpose ...

Page 15

Fusible Disconnect Switches Shafts — For use on FD400J_ BDS__ For use on FD600J_ – FD800J_ BDS_45 Twisted shafts — Rotates handle 45° BDTL26 For use on FD400J_ For use on FD600J_ – FD800J_ BDTL27 Terminal ...

Page 16

Accessories for 400A – 800A Fusible Disconnect Switches Auxiliary contacts 1 N. N. N. N.C. BDAUX_ 200A & 400A 600A & 800A Switches Switches Fuse covers (replacement part) BDZX271 BDZX272 ...

Page 17

Locking accessories Cam attachment for Kirk Key, Castell, Lowe & Fletcher and Ronis interlock. For adapting to the interlock system. The interlock is not included. Electrical interlock Closed circuit principle for interlocking the switch movement. When the coil circuit is ...

Page 18

Accessories for 400A – 800A Fusible Disconnect Switches Conversion mechanisms • Switches are not included BDZW9 pole — BDZW9 6 (8) pole mechanism allows two switches controlled by one handle, to open or close simultaneously. Equipment required ...

Page 19

For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit Side operated switches — 3 pole UL general purpose amp rating 100 200 400 CFD60J3S Handles NEMA type ...

Page 20

Flange Operated Fusible Disconnect Switches for 30A – 100A UL Fuse Class J, CC, T For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit Flange operated switches — 3 pole ...

Page 21

For a complete assembly, please select one each of the following: + Switch Fusible UL general purpose amp rating 100 200 Switch 400 600 800 Flange handles - UL 98; File #E101914 Handle Flexible cables BFCL36 - ...

Page 22

UL & cULus Technical Data for Fusible Disconnect Switches CFD30CC3 – FD800L3 Catalog number 3 pole CFD30_3 1 Approvals 2 pole N/A 3 pole UL98 & IEC 4 pole UL98 & IEC Technical ratings -40° to 40° General ...

Page 23

Catalog number 3 pole CFD30_3 Technical ratings -40° to 40°C 1 Rated insulation voltage 8 Pollution degree 3 V 1000 1000 Dielectric strength 50Hz/60Hz, 1 min kV 10 Rated impulse withstand voltage kV 12 Rated thermal current, Ith/ 2 max. ...

Page 24

IEC Technical Data for Fusible Disconnect Switches CFD30CC3 – FD800L3 Catalog number 3 pole CFD30_3 Rated breaking capacity in category AC-23A 500V A 256 690V A 256 Rated breaking capacity/poles in series in category DC-23 <220V A 128/2 440V A ...

Page 25

CFD30AJ3 - CFD60J3 CFD30AJ3 & CFD30ACC3 CFD60J3 3.94 100 1.97 50 2.23 56.6 24 for Fusible Disconnect Switches 5.04 2.55 128 1.06 64.7 27 3.62 92 0.18 4.72 4.5 120 1.59 0.55 40.5 14 5.63 143 Approximate Dimensions 0.24 6 ...

Page 26

Approximate Dimensions for Fusible Disconnect Switches 6.67 169.5 4.80 122 4.35 110.5 1.42 36.0 1.60 1.38 1.38 1.61 40 41.0 5.69 7.07 8.44 144.5 179.5 214.5 (2 pole) (3 pole) (4 pole) CFD200J03 198.63 [7.820] 144.02 [5.670] 23.88 ...

Page 27

FD400J3 0.91 23 0.28 DIA. 7 12.20 310 4.06 103 6.02 0.28 153 7 (2 Pole) 8.50 216 (2 Pole) FD600J3 & FD800L3 1.42 36 0.35 DIA. 9 14.49 368 3.74 95 8.58 0.96 218 24.5 (2 Pole) 11.26 14.80 ...

Page 28

Approximate Dimensions for Terminal Lugs BDTL24 — for use with 100A switches CDTL200 — for use with 200A switches CDTL206 — power distribution lug, for 200A switch BDTL26 — for use with 400A switches 1.50 38 3.19 81 0.63 16 ...

Page 29

BDZW6 60A - 200A pole — BDZW2 400 - 800A pole — BDZW9 28 Approximate Dimensions for 30A – 800A Conversion Mechanisms ...

Page 30

Overview for Non-Fusible Disconnect Switches CDNF16 – CDNF100A3 CDNF16A3, CDNF25A3, CDNF32A3 Catalog number 3 pole CDNF16A3 CDNF25A3 General purpose A 16 amp rating 1 Approvals 2 pole N/A 3 pole UL508 UL508 4 pole UL508 UL508 Technical ratings 2 UL, ...

Page 31

... Physical characteristics Weight 4 3 pole lb 2.90 Dimension 3 pole 3.30 Accessories Terminal lug kit CDTL200 CDTL400 • Terminal shroud • Auxiliary contact Handle UL/NEMA type • Type 1, 3R, 12 • Type 1, 3R, 4, 4X, 12 Handle type Selector — • Pistol Conversion kits • ...

Page 32

Non-Fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 16 – 100 Amp switches, 600V, 3 pole UL general purpose amp rating CDNF16A3 60 ...

Page 33

Non-Fusible Disconnect Switches Base & DIN Rail Mounted Pistol handles — for use with shafts NEMA type 1,3R,12 1,3R,12 1,3R,12 BDH56, 58 1,3R,12 1,3R,12,4,4X 1,3R,12,4,4X Shafts — for use with pistol handles BDH57 5.9/150 BDS__ 6.7/170 ...

Page 34

Accessories for 16A – 100A Non-Fusible Disconnect Switches Base and DIN rail mounted switches Auxiliary contacts mounts on right hand side of switch only CDAUX__ mounts on left hand side of switch only 1 ...

Page 35

Non-Fusible Disconnect Switches Base & DIN Rail Mounted Terminal shrouds* — snap on mounting for line or load side includes one shroud CDTS__AT3 CDTS__AT1 includes one shroud * All disconnects are IP20 touch safe as standard. ...

Page 36

Accessories for 16A – 100A Non-Fusible Disconnect Switches Conversion mechanisms • For use with Base and DIN rail mounted switches only • Switches are not included CDZW8 pole — CDZW8 6 (8) pole mechanism allows two switches ...

Page 37

For a complete assembly, please order one of each: 1 switch 1 handle 16 – 100 Amp switches, 600V, 3 pole UL general purpose amp rating CDNF16A3D CDNF25A3D 80 4 CDNF32A3D ...

Page 38

Accessories for 16A – 100A Non-Fusible Disconnect Switches Door Mounted Door mounted switches Auxiliary contacts mounts on righthand CDAUX__ mounts on left or right Max. two contacts on each side of switch Power poles • Only one power pole per ...

Page 39

Non-Fusible Disconnect Switches Terminal shrouds* — snap-on mounting for line or load side CDTS_AT3 CDTS_AT1 * All disconnects are IP20 touch safe as standard. Terminal shrouds provide an additional level of protection. Legend plates for selector ...

Page 40

Non-Fusible Disconnect Switches For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 125 Amp Base & DIN rail mounted switches UL 98 general purpose amp rating 2 pole 100 3 pole 100 125 ...

Page 41

Auxiliary contacts, top mounted • Accepts four contacts maximum, mounting base always required Mounting base – required for CDAUX_ CDAUXCA10 CDAUXCA01 Auxiliary contacts, side mounted • Accepts four contacts maximum Mounting base, required for CDAUX16011 Max. two contacts on each ...

Page 42

Accessories for 125A Non-Fusible Disconnect Switches Conversion mechanisms • For use with Base and Din rail mounted switches only • Switches are not included Transfer (1, 3R, 12) BDZW2 Mechanical interlock pole — BDZW2 6 (8) pole ...

Page 43

For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit Non-Fusible 3 pole and 4 pole 200A Switch 200 AMP, 600V UL general purpose amp rating 3 pole 200 BDH60, CDHXB86 ...

Page 44

Accessories for 200A Non-Fusible Disconnect Switches Terminal Lug Kits For use on: CDNF200U03 #4-300kcmil CDNF200U04 (6) 14-6 AWG CDTL200 Auxiliary Contacts Description 1 N.O. 1 N.C. Module for auxililary contacts CDAUX10, CDAUX01K Screw mounting to the left side of the ...

Page 45

Shaft adapter Adapts one end of a 6mm shaft to 12mm. Use with shaft extension coupler CDZK19 (X=6mm) Conversion mechanisms BDZW2 CDZW26 BDZW10 44 for 200A Non-Fusible Disconnect Switches Description For use on: 6mm shafts Weight Description ...

Page 46

... Mounting dept Weight (inches) (lbs) 10.2-14.5 0.77 12.0-16.3 0.90 17.5-21.5 1.32 Description Color (lbs) Black 0.44 Red/Yel 0.44 BDH114 CDTL400 Catalog 480V 600V number 250 350 CDNF400U03 250 350 CDNF400U04 Catalog Defeatable Padlockable Weight number (lbs) Yes Yes 0.39 BDH112 ...

Page 47

... For use on: Description of poles 3 pole Description 12mm shafts Description For use on: 12mm shafts Accessories Weight (lbs) Catalog number 0.5 CDTL400 0.5 CDTL400/3P 0.5 CDTL406 Weight (lbs) Catalog number 0.07 CDAUX10 0.07 CDAUX01K Weight (lbs) Catalog number 0.1 CDAUXM28 (lbs) Catalog number ...

Page 48

Accessories for 400A Non-Fusible Disconnect Switches Shaft adapter Adapts one end of a 6mm shaft to 12mm. Use with shaft extension coupler Conversion mechanisms CDZK19 (x=6mm) Mechanical Interlock BDZW9 BDZW12 BDZW3, 14, 15 Description For use on: ...

Page 49

For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit 600 – 800 Amp switches, 600V UL general purpose amp rating 2 pole 600 800 3 pole 600 800 4 pole ...

Page 50

Accessories for 600A – 800A Non-Fusible Disconnect Switches Terminal lug kits BDTL27 Auxiliary contacts BDTL30 1 N. N. N. N.C BDTL175/400 Terminal poles BDTL32 Detachable neutral mounts on side of ...

Page 51

Non-Fusible Disconnect Switches 90° angle kit Converts switch mechanism from front operation to side operation BDZX108 Shaft extension coupler extended length is required BDZW95 Locking accessories Cam attachment for Kirk Key, Castell, Lowe & Fletcher and ...

Page 52

Accessories for 600A – 800A Non-Fusible Disconnect Switches Conversion mechanisms • Switches are not included Mechanical interlock BDZW9 pole — BDZW9 6 (8) pole mechanism allows two switches controlled by one handle to open or close simultaneously. ...

Page 53

For a complete assembly please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit 1200 – 3150 Amp switches, 600V UL general purpose amp rating 2 pole 1200 1600 2000 3 pole 1200 1600 2000 ...

Page 54

Accessories – for 1200A 3150A Non-Fusible Disconnect Switches Twisted shafts – Rotates handle 45° For use with BDNF1200 BDS__45 For use with BDNF1600 – 3150 BDTL28 BDTL28/2 Terminal lug kits BDNF1200 & BDNF1600 BDNF1200 & BDNF16002 BDNF2000 & BDNF3150 BDTL32 ...

Page 55

Handle support bracket BDZX71 90° angle kit BDZX90 Shaft extension coupler BDZW95 Locking accessories Cam attachment for Kirk Key, Castell, Lowe & Fletcher and Ronis interlock. For adapting to the interlock system Electrical interlock Closed circuit principle for ...

Page 56

Accessories – for 1200A 3150A Non-Fusible Disconnect Switches Conversion mechanisms • Switches are not included Mechanical interlock BDZW9 pole — BDZW9 6 (8) pole mechanism allows two switches controlled by one handle to open or close simultaneously. ...

Page 57

For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit Side operated switches UL general purpose amp rating 30 60 100 175 200 BDFLNF30-S 400 600 Handles UL type For use ...

Page 58

Flange Operated Non-Fusible Disconnect Switches – 30A 200A For a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit Flange operated switches UL general purpose amp rating 30 60 100 200 Flange ...

Page 59

For a complete assembly, please select one each of the following: + Switch Non-fusible UL general purpose amp rating 30 60 100 125 200 CDNF30A3 Flange handles - UL 98; File #E101914 CDNF30 - CDNF100, CDNF160, CDNF200 Flexible cables OHF1C12 ...

Page 60

UL & cULus Technical Data for Non-Fusible Disconnect Switches CDNF16 – CDNF160 Catalog number 3 pole CDNF16A3 1 Approvals 2 pole N/A N/A 3 pole UL508 & IEC 4 pole UL508 & IEC -40° to 40°C General purpose amp rating ...

Page 61

... CDTL400 BDTL27 BDTL30 BDTL28 3 #2-600kcmil (2)#2-600kcmil (2)#2-600kcmil (4)#2-600kcmil 375 375 500 375 240 500 230 230 CDAUX_ _ BDAUX_ _ BDAUX_ _ BDAUX_ _ A600 A600 ...

Page 62

IEC Technical Data for Non-Fusible Disconnect Switches CDNF16 – CDNF160 Catalog number 3 pole CDNF16 Rated insulation and operation 40°C voltage, AC20 and DC20 1 V 750 750 Rated impulse withstand voltage kV 8 Rated thermal current open ...

Page 63

Catalog number 3 pole CDNF200U03 Rated insulation and operational 40°C voltage, AC20 and DC20 1 V 1000 1000 Rated impulse withstand voltage kV 12 Rated thermal current, Ith open 20/DC 20 250 40°C enclosed A 250 60°C ...

Page 64

IEC Technical Data for Non-Fusible Disconnect Switches CDNF16 – CDNF160 Catalog number 3 pole CDNF16 Rated voltage V/V 415 Rated conditional short-circuit current kA 50 Max. allowed fuse size, type OFAA A 16 Max. allowed cut-off current, peak ...

Page 65

Catalog number 3 pole CDNF200U03 Rated voltage, U V/V 500/690 e Rated conditional short-circuit current kA 100/80 Max. allowed fuse size, type OFAA A 350/355 Max. allowed cut-off current, peak value kA 40.5/40.5 Rated short-circuit making capacity, prospective peak value, ...

Page 66

Approximate Dimensions for Non-Fusible Disconnect Switches CDNF16A3 – CDNF100A3 CDNF16A3, CDNF25A3, CDNF32A3 — base & DIN rail mounted switch CDNF45A3, CDNF63A3 — base & DIN rail mounted switch CDNF30A3, CDNF60A3, CDNF100A3 — base & DIN rail mounted switch 65 ...

Page 67

CDNF16A3D, CDNF25A3D, CDNF32A3D — door mounted switch CDNF45A3D, CDNF63A3D — door mounted switch CDNF30A3D, CDNF60A3D, CDNF100A3D — door mounted switch 66 Approximate Dimensions for Non-Fusible Disconnect Switches CDNF16A3D – CDNF100A3D ...

Page 68

Approximate Dimensions for Non-Fusible Disconnect Switches CDNF200U03 CDNF400U03 1.65 42 BDNF600A 0.28 DIA. 7 11.93 303 4.06 103 0.31 8 1.93 49 1.58 0. 5.91 8.54 6.77 150 217 172 0.53 DIA. 13.5 3.50 89 5.85 9.35 12.85 ...

Page 69

BDNF800A 1.10 28 0.35 DIA. 9 19.21 488 3.74 95 0.94 24 8.07 205 2.07 (2 Pole) 52.5 10.71 272 (2 Pole) BDNF1200 1.10 28 0.35 DIA. 9 19.21 488 3.74 95 8.19 0. Pole) 10.71 272 (2 ...

Page 70

Approximate Dimensions for Non-Fusible Disconnect Switches BDNF1600 – BDNF3150 BDNF1600 0.35 DIA. 9 25.28 642 3.74 95 10.12 0.94 257 24 2-pole 12.63 18.11 321 2-pole 3-pole BDNF2000 – BDNF3150 0.35 DIA. 9 25.28 642 3.74 95 10.12 0.94 257 ...

Page 71

... DP [.251] REF. (2) PLCS. ?5.54/[?.218] 23.83/[.938] DP. (2) PLCS. 6.35 25.50 [.250] ?5.54/[?.218] [1.004] (2) PLCS. CDTL400/3P — for use with 400A switches 70 BDTL27 — for use with 600A switches 7.11 [.280] 17.53 [.690] 3.19 81 R2.79 [R.110] 26.92 0.53 [1 ...

Page 72

Enclosed Fusible Disconnect Switches EFJ30X-3PB6 1 3 Pole , 600V, 30A - 3150A 1 UL general purpose Fuse Catalog amp rating type number 30 J EFJ301-3PB6 30 CC EFC301-3PB6 60 J EFC601-3PB6 100 J EFJ1001-3PB8 2 200 ...

Page 73

UL general purpose Type of Catalog amp rating Switch number 1 4 Pole EFJ301-4PB6 30 (J fuses) 6 Pole EFJ301-6PB6 1 4 Pole EFC301-4PB6 30 (CC fuses) 6 Pole EFC301-6PB6 1 4 Pole EFJ601-4PB6 60 6 Pole EFJ601-6PB4 1 ...

Page 74

Accessories for Enclosed Fusible Disconnect Switches 16A – 3150A NF Auxiliary Contacts BDAUX157 Accessories BDAUX7 BDAUX8 Ground Lugs All enclosed switches are provided with a standard integral ground lug. BDAUX1 BDAUX2 Conversion mechanisms pole 6 (8) pole ...

Page 75

Pole Fusible switches Frame Enclosure Size type Height Width Depth 1 10.00 8.00 5.00 3R 10.00 8.00 5.00 CFD30_ 4 10.00 8.00 6. 10.00 8.00 5.00 4X Plastic 10.00 8.00 ...

Page 76

Enclosed Non-Fusible Disconnect Switches ENF321-3PBJ 3 Pole, 600V, 16A – 100A — Selector handle UL general purpose amp rating Pole, 600V, 16A – 3150A — Pistol handle UL general purpose amp ...

Page 77

ENF25P-3PY6 3 Pole, 600V, 16A – 100A — Selector handle Selector handles are only NEMA rated 1, 3R general purpose amp rating 16 ENF16P-3PBJ 25 ENF25P-3PBJ 40 ENF32P-3PBJ 60 ENF45P-3PBJ 80 ENF63P-3PBJ 3 Pole, 600V, 16A – 3150A ...

Page 78

Enclosed Non-Fusible Disconnect Switches Other Confi gurations UL General purpose Type of switch amp rating 4 Pole ENF161-4PB6 6 Pole ENF161-6PB6 16 Transfer ENF161-3TB8 Bypass ENF161-3BB8 Mech. interlock ENF161-3MB6 4 Pole ENF251-4PB6 6 Pole ENF251-6PB6 25 Transfer ...

Page 79

UL General purpose Type of switch amp rating 4 pole ENF16P-4PB6 16 6 pole ENF16P-6PB6 Transfer ENF16P-3TB8 Bypass ENF16P-3BB8 Mech. interlock ENF16P-3MB6 4 pole ENF25P-4PB6 25 6 pole ENF25P-6PB6 Transfer ENF25P-3TB8 Bypass ENF25P-3BB8 Mech. interlock ENF25P-3MB6 4 Pole ENF32P-4PB6 6 ...

Page 80

Enclosed Non-Fusible Disconnect Switches Other Confi gurations UL General purpose Type of switch amp rating 2 Pole ENF6001-2PB4 4 Pole ENF6001-4PB4 600 6 Pole ENF6001-6P8 Transfer ENF6001-3TB4 Bypass ENF6001-3B6 Mech. interlock ENF6001-3MB4 2 Pole ENF8001-2PB4 4 Pole ...

Page 81

UL General purpose Type of switch amp rating 2 Pole ENF600P-2PB4 4 Pole ENF600P-4PB4 600 6 Pole ENF600P-6P8 Transfer ENF600P-3TB4 Bypass ENF600P-3B6 Mech. interlock ENF600P-3MB4 2 pole ENF800P-2PB4 1 4 pole ENF800P-4PB4 800 6 pole ENF800P-6P8 Transfer ENF800P-3TB4 Bypass ENF800P-3B6 ...

Page 82

Accessories for Enclosed Non-Fusible Disconnect Switches Other Confi gurations Auxiliary contacts CDAUX_ _ Accessories CDAUXCA_ _ BDAUX_ _ Ground lugs All enclosed switches are provided with a standard integral ground lug. 3 Position selector switch Pilot light Contact For use ...

Page 83

Enclosed Non-Fusible Disconnect Switches Switch ratings, 16 – 3150 Amps, 600V UL Maximum horsepower rating General Single phase purpose amp rating 120V 200V 240V 200V – 208V 16 1/2 1.5 1 ...

Page 84

Approximate Dimensions for Enclosed Non-Fusible Disconnect Switches & 4 Pole Non-fusible switches Frame Enclosure Size type Height Width Depth 1 7.0 5.0 3.0 3R 7.0 5.0 3.0 4 6.0 6.0 4.0 CDNF16 4X SS ...

Page 85

Enclosed Non-Fusible Disconnect Switches Mechanical Interlock for Non-Fusible Enclosed Frame Enclosure Size type Height Width Depth 1 10.0 8.0 6.0 3R 10.0 8.0 6.0 4 10.0 8.0 6 CDNF16 10.0 8.0 6.0 CDNF15 4X ...

Page 86

NEMA Environmental Ratings for Enclosed Disconnect Switches Introduction An enclosure is a surrounding case constructed to provide a degree of protection to personnel against accidental contact with the enclosed equipment and to provide a degree of protection to the enclosed ...

Page 87

... CDSA3 34 CDSS200L3 11 CDSS200L4 11 CDSS200S3 11 CDSS200S4 11 CDSWM5X8 32 CDT-E 34 CDTL200 2, 10, 11, 20, 21, 27, 30, 42, 43, 58, 60 CDTL200/3P 11, 20, 43, 58, 70 CDTL206 11, 20, 27, 43, 58, 70 CDTL400 30, 45, 46, 60 CDTL400/3P 46, 70 CDTL-ST 34 CDTL-ZX58 34 CDTS100T1 34, 38 CDTS100T3 34, 38 CDTS250G1L/3 43 CDTS250G1L/4 43 CDTS250G1S/3 43 CDTS250G1S/4 43 CDZK19 9, 12, 41, 44, 47 CDZW10 41 CDZW17 35 CDZW25 ...

Page 88

Cooper Bussmann: Leading Industry in Downtime Reduction, Workplace Safety & Code Compliance Solutions Customer Satisfaction Team Available to answer questions regarding Cooper Bussmann products & services Monday-Friday, 8:00 a.m. – 4:30 p.m. for all US time zones. Contact: Phone: 636-527-3877 ...

Related keywords