CDTL400 Cooper/Bussmann, CDTL400 Datasheet - Page 65

no-image

CDTL400

Manufacturer Part Number
CDTL400
Description
Terminal Lug Kit #2-600kcmil Wire
Manufacturer
Cooper/Bussmann
Datasheet

Specifications of CDTL400

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Rated voltage, U
Rated conditional short-circuit current
Max. allowed fuse size, type OFAA
Max. allowed cut-off current, peak value
Rated short-circuit making capacity,
prospective peak value, I
Rated short time withstand current,
AC breaking capacity
DC breaking capacity/poles in series
Capacitor ratings
Rated capacitor duty
Physical characteristics
Electrical endurance at rated operational
current, pf = 0.65
Mechanical endurance
Weight
Dimension 3 pole
Power loss per one pole
Shaft size — square
Switch operating torque for
rotary 3 pole switches
Suitable conductor cross section Cu
Bolt size
Auxiliary contacts
Ratings according to IEC 947-5-1
Rated voltage, U
Thermal rated current, I
AC12/DC12 I
64
Catalog number
2 Not available at time of printing, please consult factory.
3 Size 4.
5 Maximum distance between busbar support and switch terminal 70
6 pf 0.95.
7 pf 0.65.
8 IEC 947-3, utilization category B, infrequent operation.
RMS l
RMS l
pf = 0.35
L/R = 15ms, 3 pole in series
cw
cw
e
, A U
e
i
e
=
th
cm
kA
0.2s
1.0s
48V
110V
220V
440V
750V
400/415V
3 pole
4 pole
H mm
120V
125V
240V
250V
400V
415V
440V
480V
500V
600V
690V
415V
500V
690V
operation cycles
operations
W mm
D mm
3 pole
kVar
VAC
mm
212
mm
V/V
Nm
kA
kA
35
kA
kA
kA
kg
kg
W
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
2
CDNF200U03
CDAUX_ _
40.5/40.5
500/690
350/355
100/80
1000/2
1000/2
1000/2
1000/3
1000/4
20,000
8 x 25
2000
2000
2000
1000
6 x 6
92.5
6/—
4/—
2/—
162
219
690
1.2
1.6
6.5
30
15
16
8
7
mm.
CDNF400U03
CDAUX_ _
500/690
500/500
100/80
615/59
1600/2
16,000
12 x 12
10 x 30
3200
3200
3200
1600
1000
216
260
130
690
6/—
4/—
2/—
2.2
2.6
65
28
15
10
16
16
BDNF600A
BDAUX_ _
500/690
12 x 12
12 x 40
—/0.55
—/0.31
100/50
2000/2
10,000
3/0.27
—/0.2
800
5780
4800
2800
2000
6/—
4/—
4/—
3/—
2/—
105
350
500
500
485
303
130
690
6.2
7.6
62
38
17
40
21
10
3
for Non-Fusible Disconnect Switches
Figure 1
Load
IEC
BDNF800A
BDAUX_ _
1900/2
12 x 12
12 x 60
—/0.55
—/0.31
2500
10,000
3/0.27
—/1.1
—/0.2
6400
6400
50
16.3
20.5
8/—
6/—
4/—
4/—
3/—
2/—
690
105
100
500
485
363
125
690
45
40
21
10
2
2
5
6
4
BDNF1200
BDAUX_ _
2600/2
12 x 12
12 x 60
—/0.55
—/0.31
2500
10,000
—/1.1
3/0.27
—/0.2
6400
6400
17.5
22.5
690
115
100
50
500
636
363
125
690
8/—
6/—
4/—
4/—
3/—
2/—
45
67
21
10
2
2
5
6
4
BDNF1600
BDAUX_ _
2600/2
12 x 12
12 x 60
—/0.55
—/0.31
4800
—/1.1
3/0.27
—/0.2
100 8
6400
6400
6000
690
115
110
50
636
468
271
690
8/—
6/—
4/—
4/—
3/—
2/—
45
37
47
90
50
10
2
2
5
6
4
CDNF200U03 – BDNF3150
IEC Technical Data
BDNF2000
BDAUX_ _
2600/2
12 x 12
12 x 60
—/0.55
—/0.31
4800
3/0.27
100 8
—/1.1
—/0.2
6400
6400
6000
50
8/—
6/—
4/—
4/—
3/—
2/—
690
115
110
636
468
271
690
50
37
47
90
50
10
2
2
5
7
4
BDNF3150
BDAUX_ _
2600/2
12 x 12
12 x 60
—/0.55
—/0.31
4800
3/0.27
100 8
—/1.1
—/0.2
6400
6400
6000
50
8/—
6/—
4/—
4/—
3/—
2/—
690
110
468
271
140
690
50
37
47
50
10
2
2
5
7
4
—/1.1
8/—
6/—

Related parts for CDTL400