CM150DU-12F Powerex Inc, CM150DU-12F Datasheet
CM150DU-12F
Specifications of CM150DU-12F
Available stocks
Related parts for CM150DU-12F
CM150DU-12F Summary of contents
Page 1
... Applications: £ AC Motor Control £ UPS £ Battery Powered Supplies Ordering Information: Example: Select the complete module number you desire from the table - i.e. CM150DU-12F is a 600V (V CES ), 150 Ampere Dual IGBTMOD™ Power Module. Current Rating V CES Type Amperes Volts (x 50) ...
Page 2
... V iso Symbol Test Conditions I CES CES , GES GES , GE(th 15mA 10V V CE(sat 150A 15V 25° 150A 15V 125° 300V 150A 15V 150A CM150DU-12F Units -40 to 150 °C -40 to 125 °C 600 Volts ±20 Volts 150 Amperes 300* Amperes 150 Amperes ...
Page 3
... Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM150DU-12F Trench Gate Design Dual IGBTMOD™ 150 Amperes/600 Volts Dynamic Electrical Characteristics 25°C unless otherwise specified Characteristics Input Capacitance Output Capacitance Reverse Transfer Capacitance Inductive Turn-on Delay Time Load ...
Page 4
... Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM150DU-12F Trench Gate Design Dual IGBTMOD™ 150 Amperes/600 Volts OUTPUT CHARACTERISTICS (TYPICAL) 300 25°C 9 250 V = 20V GE 200 9 150 8.5 100 COLLECTOR-EMITTER VOLTAGE (VOLTS) CE FREE-WHEEL DIODE FORWARD CHARACTERISTICS (TYPICAL 25°C ...