H5BR-B-AC100-240 Omron, H5BR-B-AC100-240 Datasheet - Page 3

no-image

H5BR-B-AC100-240

Manufacturer Part Number
H5BR-B-AC100-240
Description
TIMER DIGITAL LCD
Manufacturer
Omron
Series
H5BRr
Datasheet

Specifications of H5BR-B-AC100-240

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
SPDT (1 Form C)
Delay Time
0.001 Sec ~ 9999 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 240VAC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Timing Adjustment Method
Up/Down Digit Keys
Timing Initiate Method
Input Voltage
Lead Free Status / Rohs Status
Supplier Unconfirmed
H5BR
SPECIFICATIONS continued
Timing Charts
Output mode A1: Signal ON delay 2 (Timer resets when power comes on.)
Approvals
Operating ambient temperature
Humidity
Vibration Mechanical durability
Shock
Variation due to voltage change
Variation due to temperature change
Insulation resistance
Dielectric strength
Service life
(SPDT relay)
Output mode A: Signal ON delay 1 (Timer resets when power comes on.)
OPERATION MODES
Timing
diagram
Timing
diagram
Malfunction durability
Mechanical durability
Malfunction durability
Control output
Control output
UP
DOWN
UP
DOWN
Start signal
Start signal
Set value
Set value
Set value
Set value
Mechanical
Electrical
Power
Power
Reset
Reset
Gate
Gate
0
0
0
0
UL/ CSA/SEV/CE (EMC)
-10 to 55 C (14 to 131 F) with no icing
35% to 85% RH
10 to 55 Hz with 0.75 mm (0.03 in) single amplitude in 3 directions
10 to 55 Hz with 0.5 mm (0.02 in) single amplitude in 3 directions
30 G each in three directions
10 G each in three directions
Included in "Repeat accuracy" specification
Included in "Repeat accuracy" specification
100 M
carrying metal parts, and between non-continuous contacts.
2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminal and exposed
non-current-carrying metal parts for 100 to 240 VAC type
1,000 VAC for both 24 VAC and 12 to 24 VDC types
10 million operations minimum
100,000 operations minimum at 5 A, 240 VAC, resistive load (p.f. = 1)
Sustained output
One-shot
min. at 500 VDC between current-carrying terminal and exposed non-current-
One-shot output can be set from 0.1 s to 99.9 s.
3
Timing begins at the leading edge of
the start signal. The control output will
be energized when the present value
equals the preset time. The output will
be sustained until a reset signal is
applied, until power is interrupted, or
for a programmable one-shot time
period.
Timing begins at the leading edge of the
start signal. The control output will be
energized if the start signal is sustained
for an amount of time equal to the preset
time. The output will be sustained until
the start signal is interrupted, until a reset
signal is applied, until power is
interrupted, or for a programmable one-
shot time period.