Table 7. Package Characteristics
Notes:
1. Derate linearly above 70°C free air temperature at a rate of 0.3 mA/°C.
2. In order to achieve the absolute maximum power dissipation specified, pins 4, 9, and 10 require ground plane connections and may require
3. Maximum pulse width = 10 µs. This value is intended to allow for component tolerances for designs with I
4. This supply is optional. Required only when negative gate drive is implemented.
5. Maximum pulse width = 50 µs.
6. See the Slow IGBT Gate Discharge During Fault Condition section in the applications notes at the end of this data sheet for further details.
7. 15 V is the recommended minimum operating positive supply voltage (V
8. Maximum pulse width = 1.0 ms.
9. Once V
10. See the DESAT fault detection blanking time section in the applications notes at the end of this data sheet for further details.
11. This is the “increasing” (i.e. turn-on or “positive going” direction) of V
12. This is the “decreasing” (i.e. turn-off or “negative going” direction) of V
13. This load condition approximates the gate load of a 1200 V/150A IGBT.
14. Pulse Width Distortion (PWD) is defined as |t
15. As measured from I
16. The difference between t
17. As measured from ANODE, CATHODE of LED to V
18. This is the amount of time from when the DESAT threshold is exceeded, until the FAULT output goes low.
19. This is the amount of time the DESAT threshold must be exceeded before V
20. Auto Reset: This is the amount of time when V
21. Common mode transient immunity in the high state is the maximum tolerable dV
22. Common mode transient immunity in the low state is the maximum tolerable dV
23. To clamp the output voltage at V

Parameter
Input-Output Momentary
Withstand Voltage
Input-Output Resistance
Input-Output Capacitance
Output IC-to-Pins 9 &10
Thermal Resistance
airflow. See the Thermal Model section in the application notes at the end of this data sheet for details on how to estimate junction temperature
and power dissipation. In most cases the absolute maximum output IC junction temperature is the limiting factor. The actual power dissipation
achievable will depend on the application environment (PCB Layout, air flow, part placement, etc.). See the Recommended PCB Layout section
in the application notes for layout considerations. Output IC power dissipation is derated linearly at 10 mW/°C above 90°C. Input IC power
dissipation does not require derating.
linearly from 3.0 A at +25°C to 2.5 A at +100°C. This compensates for increased I
threshold of 12.5V. For High Level Output Voltage testing, V
approach V
IGBT protection. UVLO is needed to ensure DESAT is functional. Once V
DESAT detection and UVLO features of the ACPL-332J work in conjunction to ensure constant IGBT protection.
voltage dependent.
Reset) topic in the application information section.
output will remain in the high state (i.e., V
output will remain in a low state (i.e., V
while the output is high. See the Output Pull-Down Resistor section in the application notes at the end of this data sheet if an output pull-down
resistor is not used.
O
of the ACPL-332J is allowed to go high (V
CC
as I
OH
F
approaches zero units.
to V
O
PHL
.
and t
CC
PLH
Symbol
V
R
C
q
- 3 V
09-10
ISO
I-O
I-O
between any two ACPL-332J parts under the same test conditions.
O
< 1.0 V or FAULT < 0.8 V).
BE
O
, a pull-down resistor between the output and V
> 15 V or FAULT > 2 V). A 100 pF and a 2.1 kΩ pull-up resistor is needed in fault detection mode.
PHL
OUT
- t
OUT
will be asserted low after DESAT threshold is exceeded. See the Description of Operation (Auto
Min.
3750
PLH
CC2
| for any given unit.
- V
E
> V
Typ.
> 10
1.3
30
UVLO
OH
9
is measured with a dc load current. When driving capacitive loads, V
), the DESAT detection feature of the ACPL-332J will be the primary source of
CC2
CC2
- V
UVLO+
Max.
- V
CC2
E
E
OUT
> 12.5 V, DESAT will remain functional until V
- V
OPEAK
begins to go low, and the FAULT output to go low. This is supply
E
Units
V
W
pF
°C/W
) to ensure adequate margin in excess of the maximum V
rms
CM
CM
due to changes in V
/dt of the common mode pulse, V
/dt of the common mode pulse, V
Test Conditions
RH < 50%, t = 1 min.,
T
V
freq=1 MHz
T
EE
A
A
I-O
is recommended to sink a static current of 650 µA
= 25°C
= 25°C
= 500 V
OL
over temperature.
O
peak minimum = 2.0 A. Derate
UVLO-
CM
CM
, to assure that the
, to assure that the
Fig.
< 9.2 V. Thus, the
Note
6, 7
7
OH
UVLO+
will