Specifications of ACPL-H312-000E

Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
2.5A
Propagation Delay High - Low @ If
260ns @ 7mA ~ 16mA
Current - Dc Forward (if)
25mA
Input Type
DC
Output Type
Push-Pull, Totem-Pole
Mounting Type
Surface Mount
Package / Case
SO-8 Wide
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
ACPL-H312-000E
Quantity:
8 000
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
Notes:
1. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
2. These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by
Table 2. Insulation and Safety Related Specifications
Notes:
1. All Avago data sheets report the creepage and clearance inherent to the optocoupler component itself. These dimensions are needed as a
5
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
V
Partial discharge < 5 pC
Input to Output Test Voltage, Method a
V
Partial discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage t
Safety-limiting values
– maximum values allowed in the event of a failure.
Insulation Resistance at T
Parameter
Minimum External Air Gap
(Clearance)
Minimum External Tracking
(Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
IORM
IORM
for rated mains voltage ≤ 150 V
for rated mains voltage ≤ 300 V
for rated mains voltage ≤ 450 V
for rated mains voltage ≤ 600 V
for rated mains voltage ≤ 1000 V
Case Temperature
Input Current
Output Power
DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
means of protective circuits. Surface mount classification is Class A in accordance with CECC 00802.
starting point for the equipment designer when determining the circuit insulation requirements. However, once mounted on a printed circuit
board, minimum creepage and clearance requirements must be met as specified for individual equipment standards. For creepage, the shortest
distance path along the surface of a printed circuit board between the solder fillets of the input and output leads must be considered. There are
recommended techniques such as grooves and ribs which may be used on a printed circuit board to achieve desired creepage and clearances.
Creepage and clearance distances will also change depending on factors such as pollution degree and insulation level.
x 1.875=V
x 1.5=V
PR
, Type and Sample Test, t
PR
, 100% Production Test with t
ini
S
, V
= 10 sec)
IO
= 500 V
Symbol
L(101)
L(102)
CTI
rms
rms
rms
rms
rms
[1]
[1]
m
=60 sec,
ACPL-H312
> 175
0.08
7.0
8.0
IIIa
m
=1 sec,
ACPL-K312 Units
>175
[1]
0.08
8.0
8.0
IIIa
(ACPL-H312/K312 Option 060)
mm
mm
mm
V
Symbol
V
V
V
V
T
I
P
R
S, INPUT
S
IORM
PR
PR
IOTM
S, OUTPUT
S
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
>10
55/100/21
ACPL-H312
9
1670
1336
6000
I – IV
I – IV
I – III
I – III
891
175
230
600
2
55/100/21
ACPL-K312
1140
2137
1710
8000
>10
I - IV
I - IV
I - IV
I - IV
I - III
175
230
600
2
9
Unit
V
V
V
V
°C
mA
mW
:
peak
peak
peak
peak

Related parts for ACPL-H312-000E