HEDS-8934 Avago Technologies US Inc., HEDS-8934 Datasheet - Page 5

no-image

HEDS-8934

Manufacturer Part Number
HEDS-8934
Description
HEDS-8934 Alignment Tool, 6mm Hub
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HEDS-8934

Accessory Type
Centering Tool
Product
Tools & Accessories
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
AEAT-60xx Series
For Use With
AEAT-6012-A06 - IC ENCODER ABS MAGNETIC 12B 6MMAEAT-6010-A06 - IC ENCODER ABS MAGNETIC 10B 6MM
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Table 5. Linearity
Notes:
1. Average value at typical operating and mounting conditions.
2. Maximum value over recommended operating range and over radial & axial mounting tolerances.
Linearity Definitions
Integral non-linearity
Integral non-linearity (INL) is the maximum deviation
between actual angular position and the position
indicated by the encoder’s output count, over one revo-
lution. It is defined as the most positive linearity error
+INL or the most negative linearity error –INL from the
best fit line, whichever is larger.
Figure 3. Integral non-linearity
Table 6. Environmental Specifications
Notes:
1. Suitable for applications in Industrial Environment Class 4.
5
Parameter
Integral Non-Linearity
Differential Non-Linearity
Parameter
Electromagnetic Compatibility (EMC)
Mechanical Durability
1024
10-bit version
12-bit version
Electrostatic discharge (ESD) immunity
Power frequency magnetic field immunity
Pulse magnetic field immunity
Damped oscillatory magnetic field immunity
Vibration (Operating)
Shock
512
0
0
Most Negative Linearity Error
-INL
Angular Position (Mechanical Degree)
90
Most Positive Linearity Error
+INL
180
[1]
Symbol
INL
DNL
270
Ideal Curve
Actual Curve
Reference Standard
IEC/EN 61000-4-2
IEC/EN 61000-4-8
IEC/EN 61000-4-97
IEC/EN 61000-4-10
IEC/EN 60068-2-6
IEC/EN 60068-2-27
Min.
-
-
-
360
Differential non-linearity
Differential non-linearity (DNL) is the maximum deviation
of the step length from one position to the next.
Typ.
± 0.8
-
-
[1]
Test Conditions
8kV
30 A/m (continuous field)
300 A/m (short duration field)
1000 A/m
100 A/m
10-500Hz at 5G
6ms at 200G
Max
± 2.4
± 0.176
± 0.044
[2]
Units
Deg.
Deg.
Deg.
Notes
No missing codes
No missing codes
Level
Level 4
Level 5
Level 5

Related parts for HEDS-8934