C435 Fluke, C435 Datasheet - Page 11

Watertight Hard Storage Case With Rollers

C435

Manufacturer Part Number
C435
Description
Watertight Hard Storage Case With Rollers
Manufacturer
Fluke
Datasheet

Specifications of C435

For Use With
Fluke-430 Series 3-Phase Power Quality Analyzers
Lead Free Status / RoHS Status
na
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C43532E-12
Manufacturer:
MHS
Quantity:
20 000
Part Number:
C4354-61201
Manufacturer:
HYUNDAI
Quantity:
191
General specifications
Electro Magnetic Compatibility (EMC)
1
2
3
4
standard on the Fluke 435
11 Fluke Corporation Fluke 430 Series Three-Phase Power Quality Analyzers
Depending on clamp scaling, volt scaling 1:1
50 Hz/60 Hz nominal frequency according to IEC 61000-4-30
Add clamp accuracy and phase shift
The logger and mains signaling function are optional for the Fluke 434 and
Mechanical
Size
Weight
Power
Line power
Power adapter output voltage
Battery power
Battery operating time
Battery charging time
Power saving
Standards
Measurement methods used
Measurement performance
Power quality
Flicker
Harmonics
Cross talk
Between V inputs
Voltage to current input
Safety
Compliance
Max voltage on banana input
Max voltage on current BNC input
Environmental
Operating temperature
Storage temperature
Humidity
Maximum operating altitude
Maximum storage altitude
Warranty
Printers and Interface
Type
Baud rate
Print out facility (B&W only)
Print protocol
Emission and immunity
Frequency
80 MHz to 400 MHz
400 MHz to 600 MHz
600 MHz to 1 GHz
The Analyzer is susceptible for RF fields with a field strength of 10 V/m, between 400 MHz and 600 MHz (Performance criteria B).
cont.
256 mm x 169 mm x 64 mm (10 in x 6.5 in x 2.5 in)
2 kg (4.5 lb)
Switchable 115 V, 230 V adapter with country specific plug
15 V dc to 23 V dc; use only power adapter BC430
Rechargeable NiMH BP190 (installed)
> 7 hours
4 hours, 8 hours for/006 version (instrument off)
Adjustable time for dimmed backlight with on screen power indicator
IEC 61000-4-30 Class-A
Fluke 435 IEC 61000-4-30 Class-A, Fluke 434 IEC 61000-4-30 Class-B
EN 50160
IEC 61000-4-15
IEC 61000-4-7
-60 dB @ nominal frequency
-95 dB @ nominal frequency
IEC/EN 61010-1-2001
CAN/CSA C22.2 No 61010-1-04
UL std No 61010-1
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, Part 1: General requirements
Rated: 600 V CAT IV/1000 V CAT III Pollution Degree 2
1000 V CAT III/600 V CAT IV
42 Vpeak
0 °C to +50 °C (32 °F to 122 °F) battery only, 0 °C to +40 °C (32 °F to 104 °F) with adapter,
within spec +15 °C to +35 °C (59 °F to 95 °F)
-20 °C to +60 °C (-4 °F to +140 °F)
10 °C to 30 °C: 95 % RH non-condensing;
30 °C to 40 °C: 75 % RH non-condensing;
40 °C to 50 °C: 45 % RH non-condensing battery only
3000 m. Derate to 1000 V CAT II/600 V CAT III/300 V CAT IV above 2000 m
12 km
Three-years on mainframe, one-year on included accessories
Serial, optically isolated. Compatible with PM9080 (RS-232) or OC4USB (USB)
1200, 2400, 9600 to 115 kB
Via optional adapter PM9080 or PAC 91
Epson FX/LQ, Deskjet, LaserJet , DPU-414 or PostScript
EN61326-1
Disturbance < 0.5 %
All ranges
All other ranges
All ranges
5
6
7
8
Measured on reference voltage input A/L1
Maximum time 9999 hours
Estimated duration
Add ±(n-1) x 2.5 ° for amplitude when using i430-flex-4pk
Fluke 434/435, including standard accessories, conforms with the EEC
directive 89/336 for EMC immunity, as defined by EN61326, with the
addition of the table below
Disturbance < 10 %
125 V range