19447 Desco, 19447 Datasheet - Page 3

TEST KIT, IONIZATION, 0 TO ±19.99KV/IN

19447

Manufacturer Part Number
19447
Description
TEST KIT, IONIZATION, 0 TO ±19.99KV/IN
Manufacturer
Desco
Datasheet

Specifications of 19447

Measuring Range
0 To ±19.99kV/in
Accuracy %
5%
External Height
23.9mm
External Width
69.9mm
External Depth
125.5mm
No. Of Batteries
1
Kit Contents
19445 Meter, Plate, 9V Battery, Charger & Case
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
TB-2071 Page 3 of 3
IMPORTANT: A ground path must be provided between one of the
output terminals of the charging unit and the ground reference of
the Fieldmeter and Adapter Plate. This is normally provided by
holding the Charger in one hand and the Fieldmeter with Adapter
Plate in the other. If this is not possible, you must use a test lead
to connect one to the charger output terminals and the fieldmeter
ground connection.
Figure 6. Taking decay measurements.
Calibration
The overall accuracy of the 19447 Test Kit and the 19445 digital
fieldmeter is +/- 5% nominal. Calibration of the meter and the
Ionization Test Kit should only be performed by the factory. Both
the 19447 and the 19445 are calibrated to NIST traceable
standards. Contact our Customer Service Department for details.
Maintenance
BATTERY CARE
The battery in the Model 19447 and 19445 should be replaced
annually and whenever you plan an extended period of unattended
monitoring. See specifications for battery replacement type.
CLEANING
It is important to keep the insulators on the adapter plate clean
and free of contaminates that may cause surface leakage. To test
the performance of the adapter plate, charge the plate and note
the discharge rate in a non-ionized area. The self discharge rate to
10% of original voltage should not be less than five minutes.
The area around the aperture of the Model 19445 must be kept
clean to ensure accurate, drift-free readings. Never touch the
aperture with anything. To remove dust or other particulate matter,
use low-pressure instrument-grade air. To remove more severe
contamination, spray or flush with the smallest practical amount of
clean technical-grade of isopropyl alcohol. Then allow the
instrument to air dry for several hours.
Specifications
Isolated Plate Assembly
Plate Capacitance:
Range:
Grounding:
Weight:
DESCO EAST - 90 Hudson Road, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com
13 picofards ± 2 picofards
0 to ± 2kV, higher voltages may
be measured
Connection through conductive
case of Model 19445 Field meter
1.5 oz.
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
Charging Unit
Output:
Output Terminals:
Load Regulation:
Battery Type:
Battery Life:
Temperature Range:
Relative Humidity:
Dimensions:
Weight:
Limited Warranty
Desco expressly warrants that for a period of one (1) year from the date
of purchase, Desco Ionization Test Kits will be free of defects in material
(parts) and workmanship (labor). Within the warranty period, the product
will be tested, repaired, or replaced at Desco’s option, free of charge.
Call our Customer Service Department at 909-627-8178 (Chino, CA) or
781- 821-8370 (Canton, MA) for a Return Material Authorization (RMA)
and proper shipping instructions and address. Include a copy of your
original packing slip, invoice, or other proof of purchase factory.
Warranty repairs will take approximately two weeks.
If your unit is out of warranty call Customer Service at 909-627-8178
(Chino, CA) or 781-821-8370 (Canton, MA) for a Return Material
Authorization (RMA) and proper shipping instructions and address.
Desco will quote repair charges necessary to bring your unit up to
factory standards.
Warranty Exclusions
THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL
OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED,
INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express
warranty will not apply to defects or damage due to accidents, neglect,
misuse, alterations, operator error, or failure to properly maintain, clean
or repair products.
Limit of Liability
In no event will Desco or any seller be responsible or liable for any
injury, loss or damage, direct or consequential, arising out of the use of
or the inability to use the product. Before using, users shall determine
the suitability of the product for their intended use, and users assume all
risk and liability whatsoever in connection therewith.
1100VDC monimal, <1:A Max.
Two acorn buttons labeled for
"+" and "-"
Better than 8% NL to FL where
FL = 10 9 ohms
9 volt alkaline
40 hours
+10° to +30°C (+50° to +86°F)
10% to 80% non-condensing
3.75"L x 2.88"W x 1"D
(9.53 x 7.32 x 2.54cm)
2.8 oz. (79 gm)
© 2005 DESCO INDUSTRIES INC.
Employee Owned