CX5032SB12000F0FLJZZ AVX Corporation, CX5032SB12000F0FLJZZ Datasheet - Page 18

CRYSTAL, SM, CX-96F, 12MHZ

CX5032SB12000F0FLJZZ

Manufacturer Part Number
CX5032SB12000F0FLJZZ
Description
CRYSTAL, SM, CX-96F, 12MHZ
Manufacturer
AVX Corporation
Series
CX5032SBr
Datasheet

Specifications of CX5032SB12000F0FLJZZ

Operating Temperature Range
-30°C To +85°C
Crystal Mounting Type
SMD
Crystal Case Type
5
Frequency
12MHz
Frequency Tolerance
± 10ppm
Load Capacitance
10pF
Frequency Stability
± 10ppm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1. Shock & Drop • Vibration
3. Soldering conditions
Standard soldering iron conditions
Reflow conditions (Example)
4. Mounting Precautions
Leaded Devices
Surface Mount Devices
5. Storage Condition
Soldering iron
Time
Do not inflict excessive shock and mechanical vibration that
exceeds the norm, such as hitting or mistakenly dropping, when
transporting and mounting on a board. There are cases when
pieces of crystal break, and pieces that are used become
damaged, and become inoperable. When a shock or vibration that
exceeds the norm has been inflicted, make sure to check the
characteristics.
To maintain the product reliability, please follow recommended conditions.
The special glass, located where the lead of the retainer base comes out, is aligned with the coefficient of thermal expansion of the lead, If
the glass is damaged and cracks appear, there may be cases in which performance deteriorates and it fails to operate.
Consequently, when making the device adhere closely and applying solder, align the gap of the hole of the board with the gap of the lead
and insert without excessive force.
When making the device adhere closely to a through hole board and applying solder, be careful that the solder does not get into the metal
part of the retainer base and cause a short. Putting in an insulation spacer is one more method of preventing a short circuit.
When the lead is mounted floating, fix it as far as possible so that contact with other parts and the breakage due to the fatigue, and the
mechanical resonance of the lead will not occur.
When the lead is bent and used, do not bend the lead directly from the base, separate it 0.5mm or more and then bend it. When bending,
before attaching to the board, fix the place where the lead comes out in advance and attach it after bending so that a crack does not occur in
the glass part.
The lead of the device and the pattern of the board is soldered on the surface. Since extreme deformation of the board tears off the pattern,
tears off the lead metal, cracks the solder and damages the sealed part of the device and there are cases in which performance deteriorates
and operation fails, use it within the stipulated bending conditions. Due to the small cracks in the board resulting from mounting, please pay
sufficient attention when attaching a device at the position where the warping of the board is great.
When using an automatic loading machine, as far as possible, select a type that has a small impact and use it while confirming that there is
no damage.
Surface mount devices are NOT flow soldering compatible.
Since the long hour high temperature and low temperature storage, as well as the storage at high humidity are causes of deterioration in
frequency accuracy and solderability.
Parts should be stored in temperature range of -5 to +40°C, humidity 40 to 60% RH, and avoid direct sunlight. Then use within 6 months.
Handling Notes
Ramp-Up 1-3°C/s
Hold-Time 1-2min.
Crystal Units
Time(sec.)
260°C±5°C 10sec.(max.)
200°C min. 30-45sec.
31/0sec. max.
280°C to 340°C
Crystal Units
Cool Down 2.5-5°C/s
Recommended reflow Conditions vary depending upon products.
Please check with the respective specification for details.
- 51 -
2. Cleaning
Since a crystal piece can be broken by resonance when a crystal
device is cleaned by ultrasonic cleaning. Be careful when carrying
out ultrasonic cleaning.

Related parts for CX5032SB12000F0FLJZZ