07501 Desco, 07501 Datasheet

no-image

07501

Manufacturer Part Number
07501
Description
FOOT GROUNDER, SOLE, SMALL,2MEG
Manufacturer
Desco
Type
Premium Sole Grounderr
Datasheets

Specifications of 07501

Grounder Type
Sole
Color
White
Resistance
2Mohm
Lead Length
30"
Fastening Type
Hook And Loop
Approval Bodies
UL
Rohs Compliant
NA
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
07501914/MKL
Manufacturer:
ST
0
Part Number:
07501914/MKL
Manufacturer:
ST
Quantity:
20 000
Part Number:
0750195/MKI
Manufacturer:
ST
0
Part Number:
07501952-1
Manufacturer:
ST
0
TB-2020 December 2008 Page 1 of 2
Foot Grounders - Grounding,
Testing, and Maintenance
Description
Desco’s complete line of foot grounders has been
created to provide a continuous ground path
between the operator and a properly grounded ESD
protected flooring. Foot grounders are designed for
use in applications where user mobility is required,
such as wave solder, kitting, and quality control. Per
ANSI/ESD S20.20 Paragraph 6.2.2.2, “ESD
protective flooring used with approved footwear,
may be used as an alternative to the wrist strap
system for standing operations.” Foot grounders
quickly and effectively drain the static charges which
collect on personnel during normal, everyday
activities.
General Guidelines
1. It is recommended that foot grounders be worn
on both feet, in order to assure that a continuous
path to ground is maintained.
2. Grounding tabs should be tucked inside the shoe
with as much contact area as possible to the bottom
of the stockinged foot. Foot grounders rely upon the
perspiration in the shoe to sustain electrical contact
between the conductive grounding tab and the
body.
3. Foot grounders should be used in conjunction
with floor surfaces which have a surface resistance
of less than 1 x 10E9 ohms.
4. A current limiting one or two megohm resistor in
series with the grounding tab is recommended.
Testing Your Foot Grounders
The best test of your foot grounder is one that
includes all three components: the individual foot
grounder, the grounding tab and the interface
between the grounding tab and the wearer’s
sweatlayer.
Desco has testers designed to properly test foot
grounders. For more detailed information on these
testers, ask for technical bulletins TB-2040 (19252,
19253).
If you obtain a fail reading from the tester you should
stop working and clean the foot ground and
grounding tab. Retest after cleaning. If the unit still
fails, replace the foot grounder. Retest the system
before beginning work.
19252
DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com
TECHNICAL BULLETIN TB-2020
19253
DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449
Cleaning
Foot grounders are to ground static charges, while
dirt generally provides an insulative layer adversely
effecting reliability. For proper operation, the Foot
Grounder and its conductive strip must be kept clean.
The rubber portion of the Foot Grounder should be
cleaned using Desco’s Reztore™ Antistatic Surface &
Mat Cleaner or “Static-Wipes” wipers. An alternative
would be to clean using isopropyl alcohol. The Desco
cleaning products are specially formulated for
cleaning ESD control components and are silicone
free. This is critical as silicone is an insulator. Desco
ESD cleaners should not be used to clean the nylon
polyester grounding tab.
Foot Grounders can be safely hand or machine
washed on gentle cycle. Mild detergents, such as
Woolite
water are recommended. However, care must be
taken to ensure that these detergents are silicone
free.
Installation
HOOK & LOOP AND MARR RESISTANT
HEEL GROUNDERS
Desco model 07560, 17200, 17202, 17250, 17252,
and 17260 heel grounders are designed for use on
standard shoes. All Desco foot grounders can be
easily adjusted to fit the individual wearer. Desco heel
grounders have a dissipative lining that will not mar
white or light colored shoes. Models 07560, 17200,
17202, and 17252 have a current limiting one or two
megohm resistor in series with the grounding tab.
Models 17250 and have no resistor.
2. Insert the grounding
tab inside of the shoe
and under the foot.
Make sure that a solid contact
is made between the sock
and body. Cut grounding tab
to desired length.
grounder to confirm proper installation.
D-RING HEEL GROUNDERS
Desco model 07590 heel grounders are equipped
with an elastic D-ring fastening system which
provides snug cinching of the ankle strap and allows
"flex" during walking. They are designed for use on
most types of shoes and boots. The light blue lining
prevents marring on white or light colored shoes.
®
or a liquid dish washing product and warm
1. Place the foot grounder on
the shoe so that the lining is
GROUNDING
TAB
3. Fasten hook and loop
straps together, securing
foot grounder firmly on
shoe.
4. Test each foot
making contact with the
shoe.
LISTED
90P1
HOOK & LOOP TOE GROUNDERS
Desco model 17222 toe grounders are
designed for use on heeled shoes. Desco
toe grounders have a lining that prevents
marring on white or light colored shoes.
Model 17222 has a current limiting one
megohm resistor in series with the
grounding tab.
2. Insert the
grounding tab inside
of the shoe and
under the foot. Make
sure that a solid
contact is made
between the sock
and body. Cut
grounding tab to
desired length.
HEEL GROUNDER WITH SNAP-LOC
FASTENING SYSTEM
The Desco model 07515 heel grounders are
equipped with a Snap-Loc quick release fastening
system. The model 07515 has a cup and lining
that will not mar shoes or floors. The 07515 has a
molded exterior 2 megohm resistor.
1. Insert the grounding tab inside
of the shoe and under the foot.
Make sure that a solid contact is
made between the sock
and body. Cut
grounding tab to
desired length.
3. Test each heel grounder to confirm proper
installation.
These foot grounders include a
molded external resistor and
2. Fit the
heel cup snugly to shoe and
connect the Snap-Loc fastener
together. Adjust elastic strap
for comfortable fit. Tuck excess
elastic strap behind itself.
a permanently attached
grounding tab.
3. Pull the strap through
the D-ring and clinch
down for a snug,
comfortable fit.
4. Test each foot grounder
to confirm proper
installation.
1. Place foot grounder
on the shoe so that
the blue lining is
making contact with
the shoe.
© 2008 DESCO INDUSTRIES INC.
Made in America
GROUNDING
TAB
Employee Owned

07501 Summary of contents

Page 1

... DESCO WEST - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 DESCO EAST - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com TB-2020 December 2008 Page Cleaning ...

Page 2

... Test each toe grounder to confirm proper installation. SOLE GROUNDERS Desco model 07501, 07502, and 07503 sole grounders are designed for use on standard shoes. Desco sole grounders are available in three sizes and can be easily adjusted to fit the individual wearer. Sole grounders have a lining that prevents marring on white or light colored shoes ...