APGDT001 Microchip Technology, APGDT001 Datasheet - Page 27

LIN Serial Analyzer

APGDT001

Manufacturer Part Number
APGDT001
Description
LIN Serial Analyzer
Manufacturer
Microchip Technology
Series
-r
Datasheet

Specifications of APGDT001

Silicon Manufacturer
Microchip
Application Sub Type
Serial Analyzer
Kit Application Type
Communication & Networking
Features
Used To Send Messages, Monitor Bus Traffic, Perform Errors Checks, Filter Messages
Kit Contents
Board
Tool Type
LIN Serial Analyzer
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
PC to LIN Communications

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
APGDT001
Manufacturer:
MICROCHIP
Quantity:
12 000
3.7
3.8
FIGURE 3-7:
© 2008 Microchip Technology Inc.
START/STOP LOGGING BUTTON
MASTER MESSAGE GROUP BOX
This button – located in the top, right corner of the interface – starts, pauses, or stops
the capturing of messages to the log file.
Before starting the logging process, select and open a log file (see Section 3.5.2 “Log
File”).
To pause the logging process, click the button a second time.
This functions in the group box to act as a master node on the LIN bus, sending the
previously constructed frames to the slaves on the bus.
This window will cause a bus conflict if another master appears on the network. Any
conflict will be shown in an active Transaction window as a bus error.
The group box, shown in Figure 3-7, consists of the:
• “Master Frames” field
• “Checksum” group
• Message controls
MASTER MESSAGE GROUP BOX
3.8.1
The “Master Frames” field is composed of 0 to n rows of one or more messages that
can be sent over the bus for test purposes. These messages can be entered manually,
loaded from a previously saved session, or both.
When the message is sent, it and any response is displayed in the Transaction window
if it is open and active.
Messages in the “Master Frames” field can also be saved for reuse (see
Section 3.4.2 “Save” and Section 3.4.3 “Save As”).
3.8.1.1
Messages must consist of the ID byte without parity bits and the data bytes, all
separated by spaces. All inputs are in hexadecimal radix.
The checksum is not included; it is calculated at send time.
Comments or notes may be attached to each frame by prefacing it with a
semi-colon (;). Any text after the semi-colon will be disregarded and not transmitted. All
notes will be saved in the selected .ini file and reloaded when reopened.
Master Frames Field
MESSAGE SYNTAX
LIN Serial Analyser PC Program
“Master Frame
Field
“Checksu
Group
Message
Controls
DS51675B-page 23

Related parts for APGDT001