EVAL-ADXL330Z Analog Devices Inc, EVAL-ADXL330Z Datasheet - Page 13

Three-Axis Accelerometer Evaluation Board

EVAL-ADXL330Z

Manufacturer Part Number
EVAL-ADXL330Z
Description
Three-Axis Accelerometer Evaluation Board
Manufacturer
Analog Devices Inc
Series
iMEMS®r
Datasheets

Specifications of EVAL-ADXL330Z

Silicon Manufacturer
Analog Devices
Application Sub Type
Accelerometer - Three-Axis
Kit Application Type
Sensing - Motion / Vibration / Shock
Silicon Core Number
ADXL330
Sensor Type
Accelerometer, 3 Axis
Sensing Range
±3.6g
Interface
Analog
Sensitivity
300mV/g
Voltage - Supply
1.8 V ~ 3.6 V
Embedded
No
Utilized Ic / Part
ADXL330
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Q2904641
The ADXL330 output is ratiometric, therefore, the output
sensitivity (or scale factor) varies proportionally to the
supply voltage. At V
typically 360 mV/g. At V
typically 195 mV/g.
The zero g bias output is also ratiometric, so the zero g output is
nominally equal to V
The output noise is not ratiometric but is absolute in volts;
therefore, the noise density decreases as the supply voltage
increases. This is because the scale factor (mV/g) increases
while the noise voltage remains constant. At V
X- and Y-axis noise density is typically 230 μg/√Hz, while at
V
Self test response in g is roughly proportional to the square of
the supply voltage. However, when ratiometricity of sensitivity
is factored in with supply voltage, the self test response in volts
is roughly proportional to the cube of the supply voltage. For
example, at V
approximately −275 mV for the X-axis, +275 mV for the Y-axis,
and −100 mV for the Z-axis.
S
= 2 V, the X- and Y-axis noise density is typically 350 μg/√Hz.
S
= 3.6 V, the self test response for the ADXL330 is
S
S
= 3.6 V, the output sensitivity is
/2 at all supply voltages.
S
= 2 V, the output sensitivity is
X
Y
Z
OUT
OUT
OUT
= 0g
= 0g
= 1g
TOP
S
Figure 32. Output Response vs. Orientation to Gravity
= 3.6 V, the
X
Y
Z
X
Y
Z
OUT
OUT
OUT
OUT
OUT
OUT
TOP
TOP
= 0g
= 1g
= 0g
= –1g
= 0g
= 0g
Rev. A | Page 13 of 16
TOP
X
Y
Z
X
Y
Z
OUT
OUT
OUT
OUT
OUT
OUT
At V
the X-axis, +60 mV for the Y-axis, and −25 mV for the Z-axis.
The supply current decreases as the supply voltage decreases.
Typical current consumption at V
typical current consumption at V
AXES OF ACCELERATION SENSITIVITY
Figure 31. Axes of Acceleration Sensitivity, Corresponding Output Voltage
= 0g
= 0g
= –1g
= 1g
= 0g
= 0g
S
= 2 V, the self test response is approximately −60 mV for
A
Z
Increases When Accelerated Along the Sensitive Axis
GRAVITY
X
Y
Z
OUT
OUT
OUT
= –1g
= 0g
= 0g
A
Y
S
S
= 2 V is 200 μA.
= 3.6 V is 375 μA, and
ADXL330
A
X