UG-012
INERTIAL SENSOR EVALUATION SYSTEM GRAPHICAL USER INTERFACE
CONFIGURATION TAB
When the system is set up and configured, press SW2, which is
shown in Figure 9, to reset the ISEB and have it detect the
currently connected satellite. This must be done when the
satellite connected to the ISEB is replaced by a satellite of a
different part only; replacing the satellite with a satellite for the
same part, that is, an EVAL-ADXL346Z-S with another EVAL-
ADXL346Z-S, does not require SW2 to be pressed.
The inertial sensor evaluation system GUI is opened by executing
the ADXL346 Evaluation GUI.exe file located in the /ADXL346
Evaluation GUI/ folder. To exit the GUI, use the Stop VI button to
disconnect from the ISEB. Then exit the application by selecting
File and Exit or by pressing Ctrl+Q.
The first screen brought up is the Configuration tab (see Figure 10).
This screen is used for manual configuration of the sensor, for
setting up the communication port between the PC and ISEB,
and for setting the sensor voltage values. Configuration register
values can be saved and reloaded.
It is important to note that the register settings entered on this
screen are independent from other GUI screens. Each screen
requires a different register setup, and any values that can be
altered are made available for that particular screen.
With the Configuration tab open, select the correct COM port
for the ISEB from the VISA Resource Name menu (see Figure 10).
The correct COM port can be found by checking the Device
Manager for the ADI Inertial Sensor Evaluation System under
the Ports (COM & LPT) selection.
After selecting the COM port, click on Connect to connect to
the ISEB. This causes the indicator under Vs Set to light up and
update the Current Vs [V] value, verifying that the board is
connected (see Figure 11).
Figure 10. Selecting the Correct COM Port for the ISEB
Rev. 0 | Page 6 of 12
Clicking the round button above Vs Set causes the supply
voltage, V
in the Desired Vs [V] box. The Current [μA] and Temp [degC]
boxes are also updated whenever the Vs Set button is clicked.
Read the contents of the ADXL346 registers by clicking the
Read All Registers button in the Register Write box. This
action updates all register values and indicators on the right side
of the screen. Figure 11 depicts a sensor that is powered on with
a DevID of 0xE5, a BW/RATE value of 0x0A, and an
INT_SOURCE value of 0x02. All other registers remain in their
default state of 0x00.
To write a value to a register, select the register from the Target
Register menu and click the D7 through D0 indicators to set the
value. If an indicator is lit, the value written to that bit is a Logic
1, whereas an unlit indicator indicates a Logic 0. When the register
is configured correctly, click the Write Register button to send the
value to the ADXL346. Note that the D7 through D0 indicators
under Target Register are not updated based on the value
stored in that register.
To save a configuration, click the Save Config button under
Configuration File (see Figure 11). Save the file with a .txt
extension. After a configuration is saved, you can load the
configuration back into the device by clicking the Load Config
button and selecting the configuration file.
S
, of the ADXL346 to be updated based on the value
Evaluation Board User Guide
Figure 11. ISEB Connected to PC