MB2146-251 Fujitsu, MB2146-251 Datasheet - Page 10

no-image

MB2146-251

Manufacturer Part Number
MB2146-251
Description
HEADER BOARD, QFP-100P, 8FX
Manufacturer
Fujitsu
Series
F2MC-8FXr
Datasheet

Specifications of MB2146-251

Convert From
100-QFP
Convert To
Header Board
Pitch Spacing
0.65mm
Row Pitch
19.8mm
Ic Adapter Type
QFP-100
Mcu Supported Families
F2MC-8FX
Mounting Type
SMD
Supported
RoHS Compliant
6. Mounting Mass Production MCUs
■ Mounting
■ Disconnection
To mount a mass production MCU on the user system, use the supplied HQPACK (IC socket cover)
(See Figure 6) .
1. To mount a mass production MCU on the user system, match the index mark (▲) on the NQ-
2. Confirm that the mass production MCU is correctly mounted on the NQPACK. Next, match the
3. Insert each screw for securing HQPACK in each of four drilled holes on the HQPACK, and then
To remove the HQPACK, remove all of the four screws and pull out the HQPACK vertically from
the NQPACK. When you take out the mass production MCU, the mass production MCU is handled
by using a vacum pick-up tool. Do not attempt to remove the mass production MCU forcibly, for
example, using a screwdriver as doing so can bend the pins of the mass production MCU or break
the NQPACK.
PACK mounted on the user system with the index mark (●) on the mass production MCU.
index mark of HQPACK with the index mark of NQPACK and insert it (angle cut linearly at one
place only) .
The pin of HQPACK is thin and easy to bend. Insert NQPACK after confirm that the pin of HQ-
PACK is not bent.
tighten the screws diagonally.
To tighten the screws, use the special screwdriver supplied with the NQPACK to finally tighten
the four screws in sequence. Tightening the screws too tight might result in a defective contact.
User system
Figure 6 Mounting a mass production MCU
NQPACK
Mass production MCU
HQPACK
Screws for securing HQPACK
7

Related parts for MB2146-251