739880 YOKOGAWA, 739880 Datasheet - Page 19

no-image

739880

Manufacturer Part Number
739880
Description
NIMH BATTERY, 10.8V, 210mAH
Manufacturer
YOKOGAWA
Datasheet

Specifications of 739880

Battery Capacity
210mAh
Battery Voltage
10.8V
Battery Technology
Nickel Metal Hydride
Voltage Rating
10.8V
Lead Free Status / RoHS Status
na
Making 32-bit logic signals easy to read and understand
Logic signal measurement and analysis
Observing up to 32-bit logic signals together with analog signals
Observing many signals simultaneously and checking their
correlations and timing is an effective means of verifying
increasingly complex embedded systems.
With the DLM6000 series, you can measure up to 32-bit logic
signals and 4 channels of analog waveforms simultaneously,
and investigate hidden data in waveforms using bus analysis
and computation functions.
Grouping logic signals to make them easy to read and understand
As many as 5 groups of logic signals can be defi ned. You can
enter display settings for each group, and specify bit arrangement
in each group regardless of the bit arrangement of the logic probe.
This means that even if pin assignments or signal arrangements
change, you only need to change settings rather than to repeat
the probing of the circuit.
• Easy-to-read address bus and data bus displays
• Even if device pin assignments or signal arrangements
Bus and State displays make logic signals easy to read and analyze
The DL6000/DLM6000 can show logic signals assigned to groups
in a Bus display, or specifi ed clock signals in a State display.
With clock synchronization, you can display logic signals in
binary or hexadecimal format, so parallel output values of an
address bus or A/D converter can be analyzed easily, and
operating checks of the device under test can be performed
more quickly and accurately.
Virtual D/A Computation function displays up to 32-bit logic signals
as analog waveforms
Even a one-bit error of digital signals is a big problem. It is diffi cult
to fi nd such a digital error with logic waveforms alone.
With a Virtual D/A Computation function, you can convert digital
data into analog waveforms and display them to make data
verifi cation easier.
• Easy verifi cation of address bus and data bus
• Real time comparison and verifi cation of analog waveforms
• D/A converted waveforms can undergo FFT analysis or have
change, you only need to change settings
and digital values prior to and after A/D or D/A conversion.
additional digital fi ltering computations applied to them.
Clock
1C
1C
1C
1C
State display: Normalization based on a specified clock edge
27
27
27
27
for the group. The logic signals within each group
Displayed for each group in the bit order defined
and their bit orders are not restricted to the bit
3F
3F
3F
3F
Virtual D/A Computation waveform
arrangement of the logic probe.
Original analog waveform
OA
OA
OA
OA
Logic signals
1C
Bus display of an
8-bit logic signal
27
3F
OA
*1: Logic probes sold separately. Please order the model 701988/701989 accessory logic probes separately.
*2: Only one of these may be selected at a time.
*3: Specify this option when using current probes or other differential probes such as models 701920 or 701922.
*4: Only one of these may be selected at a time.
*5: Only one of these may be selected at a time.
UART/CAN/LIN/I2C/SPI
Analyzing switching circuit characteristics
DL6054
DL6104
DL6154
Power cable
Help language
Option
DLM6054 *
DLM6104 *
Power cable
Help Language
Logic input
Option
Model
DL6054/6104/6154
DLM6054/6104
Model
With an Auto Setup function for serial bus analysis, the DL6000/
Serial bus analysis function (option)
DLM6000 series automatically performs the tedious task of
entering settings. You just need to select the bus type and input
channel, and the oscilloscope will automatically recognize
the waveform, set parameters such as a bit rate, and display
analysis results instantaneously. Also, two different busses can
be analyzed at the same time. For example, you can analyze a
CAN and LIN bus simultaneously.
Power supply analysis function (option)
By using combinations of differential and current probes, you
can evaluate the switching loss or analyze the safe operating
area (SOA) in power supply waveforms. Through statistical
computation you can also measure multiple switching waveforms
and display the loss on a per-period basis in lists and trends, or
display statistics on the aggregate loss of up to 2,000 switching
waveforms stored in History Memory. If precise calculations are
required, a correction function and High Resolution mode are
available.
1
1
Suffix Code
-D
-F
-Q
-R
-H
-D
-F
-Q
-R
-H
-HE
-HC
-HK
-HG
-HF
-HL
-HS
Suffix Code
-HE
-HC
-HK
-HG
-HF
-HL
-HS
/B5
/P2 *
-L16 *
-L32 *
/C9 *
/C12 *
/B5
/G2 *
/G4 *
/P4 *
Models and Suffi x Codes
3
/F3
2
2
/C9 *
/C12 *
4
/F4
4
/G2 *
/G4 *
5
5
3
/F3
Analysis Functions
4
/F4
4
5
5
4CH 500MHz,Max. 5GS/s(2.5GS/s/CH), 6.25 Mpts/CH
4CH 1GHz,Max. 5GS/s(2.5GS/s/CH), 6.25 Mpts/CH
4CH 1.5GHz,Max. 10GS/s(5GS/s/CH), 6.25 Mpts/CH
UL/CSA standard
VDE standard
BS standard
AS standard
GB standard
English Help (Menu and Panel)
Chinese Help (Menu and Panel)
Korean Help (Menu and Panel)
German Help (Menu and Panel)
French Help (Menu and Panel)
Italian Help (Menu and Panel)
Spanish Help (Menu and Panel)
Built-in printer
Probe power
Internal storage + LXI compliant LAN
LXI compliant LAN
User defined Math
Power supply analysis function (includes /G2)
UART+I
UART+CAN+LIN trigger and analysis
4CH 500MHz+Logic16/32bit,
Max. 5GS/s(2.5GS/s/CH), 6.25Mps/CH
4CH 1GHz+Logic 16/32bit,
Max. 5GS/s(2.5GS/s/CH), 6.25Mps/CH
UL/CSA standard
VDE standard
BS standard
AS standard
GB standard
English Help (Menu and Panel)
Chinese Help (Menu and Panel)
Korean Help (Menu and Panel)
German Help (Menu and Panel)
French Help (Menu and Panel)
Italian Help (Menu and Panel)
Spanish Help (Menu and Panel)
Logic 16bit (Logic probe interface x 2)
Logic 32bit (Logic probe interface x 4)
Built-in printer
Probe power
Internal storage + LXI compliant LAN
LXI compliant LAN
User defined Math
Power supply analysis function (includes /G2)
UART+I
UART+CAN+LIN trigger and analysis
2
C+SPI trigger and analysis
2
C+SPI trigger and analysis