AEDA-3300-TDM Avago Technologies US Inc., AEDA-3300-TDM Datasheet - Page 7

M-Aries Kit,3Ch,18000CPR,Top Mt

AEDA-3300-TDM

Manufacturer Part Number
AEDA-3300-TDM
Description
M-Aries Kit,3Ch,18000CPR,Top Mt
Manufacturer
Avago Technologies US Inc.
Series
AEDA-3300r
Type
Optical Encoderr
Datasheet

Specifications of AEDA-3300-TDM

Encoder Type
Optical
Output Type
Quadrature with Index (Incremental)
Pulses Per Revolution
18000
Voltage - Supply
5VDC
Actuator Type
2mm Open Center
Detent
No
Built In Switch
No
Mounting Type
Chassis Mount, Motors
Orientation
Vertical
Termination Style
Terminal Pins
Detents
No
Motion
Rotary
Number Of Channels
3
Mounting Style
Through Hole
Index Output
Indexed
Encoder Signal
Digital Square Wave
Shaft Style
Hollow
Shaft Diameter (mm)
2mm
Operating Supply Voltage (typ)
5VDC
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
125C
Terminal Type
PC Pins
Supply Voltage
5 V
Product
Kits
Technology
Rotary
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rotational Life (cycles Min)
-
Lead Free Status / Rohs Status
Compliant
Output Waveforms
Definitions
Count (N): N refers to the cycles per revolution
(CPR) of the encoder output.
One Cycle (C): 360 electrical degrees (°e).
One Shaft Rotation: 360 mechanical degrees,
N cycles (rotary motion only).
Phase (φ): The number of electrical degrees
between the center of the high state on the
channel A and the center of the high state of
channel B. This value is nominally 90 °e.
Pulse Width (P): The number of the electrical
degrees that an output is a high-level during
one cycle, nominally 180 °e or 1/2 a cycle.
7
Amplitude
S1
P
S2
Codewheel Rotation (Counter-clockwise )
C
S3
S4
Po
Pulse Width Error (∆P): The deviation in
electrical degrees of the pulse width from its
ideal value of 180 °e.
Index Pulse Width (Po): The number of
electrical degrees that an index is high during
one full shaft rotation. This value is nominally
180 °e or 1/2 cycle. 90 °e (1/4 cycle) index
pulse width available upon request.
State Width (S): The number of the electrical
degrees between transitions in the output of
the channel B. There are 4 states per cycle,
each nominally 90 °e.
State Width Error (∆S): The deviation in
electrical degrees of each state width from its
ideal value of 90 °e.
2.5 V
0.5 V
2.5 V
0.5 V
2.5 V
0.5 V
2.5 V
0.5 V
0.5V
2.5 V
2.5 V
0.5 V
CH. A
CH. B
CH. I
CH. B-
CH. I-
CH. A-