OPIA400ATU Optek, OPIA400ATU Datasheet - Page 37

Transistor Output Optocouplers 50mA 50-600CRT%

OPIA400ATU

Manufacturer Part Number
OPIA400ATU
Description
Transistor Output Optocouplers 50mA 50-600CRT%
Manufacturer
Optek
Datasheet

Specifications of OPIA400ATU

Maximum Fall Time
18 us
Maximum Input Diode Current
50 mA
Maximum Reverse Diode Voltage
6 V
Maximum Rise Time
18 us
Output Device
Phototransistor
Output Type
DC
Configuration
1 Channel
Input Type
DC
Maximum Collector Emitter Voltage
60 V
Maximum Collector Emitter Saturation Voltage
0.2 V
Isolation Voltage
5000 Vrms
Current Transfer Ratio
600 %
Maximum Forward Diode Voltage
1.4 V
Maximum Collector Current
50 mA
Maximum Power Dissipation
200 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 30 C
Package / Case
PDIP-4 Gull Wing
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Quality / Reliability Requirements
Note: This is to be performed when a change occurs to form, fit or function.
Optocoupler—SMD, SOP and SSOP Packages
OPIA400 through OPIA414
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
Label Identification
DESCRIPTION:
Notes:
HTRB D I
HTFB D I
MTTF @ 90% confidence
Moisture Sensitivity Level
Lead Solderability
Glass Transition of body
Temperature Humidity-Bias
Temperature Cycle
High Temperature Storage
Autoclave
1. The DATE CODE is a 4-digit code for date of manufacture where YY is
2. The LOT I.D. is the manufacturing location lot identification where Y is
the last two digits of the year, and WW is week number of manufacture.
the year of manufacture, NNNN is a sequential lot identifier, and DDD is
the day of the year of manufacture. – or use equivalent label format.
Size: 3” (7.4 cm) X 2.2” (5.5 cm)
Lettering shall be black on white background.
Format shall be as:
C(ON)
C(OFF)
Parameter
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
European Union’s Reduction of Hazardous Substances (RoHS) Directive 2002/95/EC
FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
Government and Industry Standard
Compliance Requirements
Failure Criteria
150,000 Min.
125°C Min.
MSL 1
± 10%
± 10%
± 20%
± 20%
± 20%
0 Fail
0 Fail
0 Fail
0 Fail
T
per Method 1010.7 of MIL-STD-883E
85°C, 85%RH, 500Hrs, 80% min Iceo
A
= 121°C, Pressure = 15psi, Humidity
per Method 208 of MIL-STD-202.
@ VCE = 5.0VDC, Ta = 70°C
per JDEC stnd J-STD-020B
IIIIIIIIIIIIIIIIIIIII
IIIIIIIIIIIIIIIIIIIII
IIIIIIIIIIIIIIIIIIIII
IIIIIIIIIIIIIIIIIIIII
11 samples after 500Hrs
DATE CODE _____(YYWW)___
50 samples after 96Hrs
LOT I.D. ____(Y-NNNNDDD)__
= 100%, Time = 96Hrs
OPTEK P/N __OPIA407C-TR__
@ Max P
QTY. ________N/A_________
@ 25°C, 25mADC
DSC test method
85°C, 500Hrs
Carrollton, TX, USA
MADE IN TAIWAN
Conditions
D
, Ta = 25°C
Issue A .4
Page 37 of 41
11/08

Related parts for OPIA400ATU