3. HARDWARE DESCRIPTION
3.1
Observe the following limits to ensure the CDB5571 component ratings are not exceeded.
3.2
Power supply connections and requirements are specified in Table 1. below.
Important: It is recommended that all power supplies be isolated from utility ground to prevent the intro-
duction of a ground loop. One ground connection may already exist through the serial port connection to
utility ground. Using the Cirrus Logic CapturePlus II system simplifies making connections to the
CDB5571 by providing electrical isolation between the two.
Using twisted/shielded wire will reduce electrical noise induced onto the power supply cables.
Power supplies are to be adequately regulated and sufficiently low noise to meet the application require-
ments.
3.3
3.3.1
The analog input signal connections to the input buffers are made at the IN_A and IN_B connectors, as
specified in Table 2.
There are two analog input channels on the evaluation board. Each analog input channel consists of a
low-noise amplifier configured as a unity gain non-inverting buffer. The buffers utilize a Cirrus Logic
CS3004 precision, low-noise, low-voltage, dual opamp.. These op-amps enable both the inputs and out-
puts of the analog input buffer to operate virtually rail to rail. The channel input impedance is 50 Ohms.
6
+2.5 V DC, ±5%, <50 mA
+3.3 V DC, ±5%, <50 mA
-2.5 V DC, ±5%, <50 mA
Power Supply
Absolute Maximum Ratings
• CS5571
• CS3004
Power Supply
Requirement
Analog Section
Analog Input Buffers
Channel
IN_A
IN_B
– The absolute maximum supply voltage that can be applied to the +3.3V power supply
– The absolute maximum power supply voltage that can be applied between pins VL and V1-
– The absolute maximum power supply voltage that can be applied between the +2.5V and
connection is +3.6V.
is 6.1 V.
-2.5V power supply connections is +5.5V.
Power Supply
Analog Input
Connection
Connection
Table 1. Power Supply Connections
Table 2. Analog Input Connections
E16
J10
J11
E5
E9
-2.048 V to +2.048 V
-2.048 V to +2.048 V
Ground Return
Voltage Range
Input Signal
Associated
E13
E3
E7
TP2, TP1 (GND)
TP4, TP3 (GND)
TP6, TP5 (GND)
Associated
Test Points
Impedance
50 Ohms
50 Ohms
CDB5571