CRD-5376 Cirrus Logic Inc, CRD-5376 Datasheet - Page 46

Audio Modules & Development Tools Ref Bd LP Mlt-Ch Decimation Filter

CRD-5376

Manufacturer Part Number
CRD-5376
Description
Audio Modules & Development Tools Ref Bd LP Mlt-Ch Decimation Filter
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CRD-5376

Description/function
Audio D/A
Operating Supply Voltage
3.3 V
Product
Audio Modules
Supply Current
300 mA
For Use With/related Products
CS3301A, CS3302A, CS4373A, CS5371A, CS5372A, CS5376A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3.5.1
The DF Registers sub-panel writes and reads registers within the digital filter. Digital filter registers con-
trol operation of the digital filter and the included hardware peripherals, as described in the digital filter
data sheet.
3.5.2
The DF Commands sub-panel sends commands to the digital filter. The digital filter commands and their
required parameters are described in the digital filter data sheet.
Not all commands require write data values, and not all commands will return read data values. Some
commands require formatted data files for uploading custom coefficients or test bit stream data Example
formatted data files are included in the SPI sub-directory of the software installation.
3.5.3
The SPI sub-panel writes and reads registers in the digital filter SPI register space. They can be used to
check the SPI serial port status bits or to manually write commands to the digital filter.
46
Address
Data
Read
Write
Command
Write Data 1
Write Data 2
Read Data 1
Read Data 2
Send
Start Address
Data Word 1
Data Word 2
Data Word 3
Read 1 Word
Read 3 Words
Write 1 Word
Write 3 Words
Control
Control
Control
DF Registers
DF Commands
SPI
Selects a digital filter register.
Contains the data written to or read from the register.
Initiates a register read.
Initiates a register write.
Selects the command to be written to the digital filter.
Contains the SPI1DAT1 data to be written to the digital filter.
Contains the SPI1DAT2 data to be written to the digital filter.
Contains the SPI1DAT1 data read from the digital filter.
Contains the SPI1DAT2 data read from the digital filter.
Initiates the digital filter command.
Selects the address to begin the SPI transaction.
Contains the first data word written to or read from the SPI registers.
Contains the second data word written to or read from the SPI registers.
Contains the third data word written to or read from the SPI registers.
Initiates a 1 word SPI read transaction.
Initiates a 3 word SPI read transaction.
Initiates a 1 word SPI write transaction.
Initiates a 3 word SPI write transaction.
Description
Description
Description
CRD5376
DS612RD2

Related parts for CRD-5376