SX-550-0700 Silex Technology, SX-550-0700 Datasheet - Page 108

WiFi / 802.11 Modules & Development Tools Wired Internal OEM 10/100 Serial Server

SX-550-0700

Manufacturer Part Number
SX-550-0700
Description
WiFi / 802.11 Modules & Development Tools Wired Internal OEM 10/100 Serial Server
Manufacturer
Silex Technology
Datasheet

Specifications of SX-550-0700

Interface Type
RS-232, SPI
Security
802.1x
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SH POWER
SET LOAd ENable
SET LOAd HOst
SET LOAd IP
SET LOAd SOftware
SET LOAd TFTP
SET LOAd XModem
SH LOAd
Firmware Update
Part Number 40183-101
Command
Sets the firmware to perform a soft reset and enter the server boot program after the
next Exit command.
This command is used for diagnostic purposes only.
The default value is Disable.
Format:
Sets the node name of the Netware boot host.
This command is used for diagnostic purposes only.
The default value is null>\
Format:
Sets source computer IP address for TFTP get operation.
The default value is 0.0.0.0.
Format:
Sets filename on host for TFTP get update
Format:
Initiates firmware update using TFTP get operation.
The TFTP server address must be set using SET LOAd IP and the filename using
SET LOAd SOftware. The server will reset after the firmware update is completed.
Format:
Initiates firmware update using the XModem protocol on the serial console
The server will reset after the firmware update is completed.
Format:
Shows the firmware update parameters
Sample output:
SET LOAd (ENable | DIsable ]
SET LOAd HOst
SET LOAd IP
SET LOAd SOftware
SET LOAd TFTP
SET LOAd XModem
Firmware load is disabled
Load Host IP
Table 42 Firmware Update
Shows the current power control mode.
Silex SX-550 Developer's Guide