PC404A-210 TAOS, PC404A-210 Datasheet
PC404A-210
Specifications of PC404A-210
Related parts for PC404A-210
PC404A-210 Summary of contents
Page 1
... An oscilloscope is required for observation and analysis of the output signals. 2. Functional Description The linear sensor array support circuitry of the PC404A consists of an oscillator, a counter/divider and logic to provide the imager with the required clock and integration pulse signals for operation. The oscillator is built around a TLC555 timer. The oscillator output is inverted and fed into divider U10 to provide lower frequency options ...
Page 2
... Figure 2 - System Timing (AO output for TSL1401 shown) 3. Operation To operate the PC404A, apply 5VDC to the board using a regulated lab power supply. Connect an oscilloscope probe to the Ao terminal and the scope ground to one of the GND terminals. For best results, connect another probe to the SI terminal and use that signal to trigger the oscilloscope ...
Page 3
... Figure 3 - PC404A Silkscreen (top side) Table and W2 Jumper Configuration DEVICE TSL1301 / 1401R / 201R TSL1402R / TSL202R TSL1406R / TSL1410R / TSL1412R TSL208 TSL210R TSL2014 JUMPER W1 JUMPER W2 Open 2-3 2-3 Open Open Open 1-2 2-3 2-3 Open Open Open ...