AD71056ARZ-RL Analog Devices Inc, AD71056ARZ-RL Datasheet - Page 6

no-image

AD71056ARZ-RL

Manufacturer Part Number
AD71056ARZ-RL
Description
IC,Power Metering,CMOS,SOP,16PIN,PLASTIC
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD71056ARZ-RL

Input Impedance
320 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.8V
Current - Supply
5mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-SOIC (0.154", 3.90mm Width)
Meter Type
Single Phase
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD71056ARZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD71056
TERMINOLOGY
Measurement Error
The error associated with the energy measurement made by the
AD71056 is defined by the following formula:
Phase Error Between Channels
The high-pass filter (HPF) in the current channel (Channel V1)
has a phase-lead response. To offset this phase response and
equalize the phase response between channels, a phase correction
network is also placed in Channel V1. The phase correction
network matches the phase to within 0.1° over a range of 45 Hz
to 65 Hz, and 0.2° over a range 40 Hz to 1 kHz (see Figure 23
and Figure 24).
Power Supply Rejection (PSR)
This quantifies the AD71056 measurement error as a
percentage of reading when the power supplies are varied.
For the ac PSR measurement, a reading at nominal supplies
(5 V) is taken. A 200 mV rms/100 Hz signal is then introduced
onto the supplies and a second reading is obtained under the
same input signal levels. Any error introduced is expressed as a
percentage of reading—see the Measurement Error definition.
For the dc PSR measurement, a reading at nominal supplies
(5 V) is taken. The supplies are then varied 5% and a second
reading is obtained with the same input signal levels. Any error
introduced is, again, expressed as a percentage of reading.
%
Error
=
Energy
Registered
True
by
AD71056
Energy
True
Energy
×
100
Rev. A | Page 6 of 20
%
ADC Offset Error
This refers to the small dc signal (offset) associated with the
analog inputs to the ADCs. However, the HPF in Channel V1
eliminates the offset in the circuitry. Therefore, the power
calculation is not affected by this offset.
Frequency Output Error (CF)
The frequency output error of the AD71056 is defined as the
difference between the measured output frequency (minus the
offset) and the ideal output frequency. The difference is
expressed as a percentage of the ideal frequency. The ideal
frequency is obtained from the AD71056 transfer function. See
Figure 14 for a typical distribution of part-to-part variation of
CF frequency.
Gain Error
The gain error of the AD71056 is defined as the difference
between the measured output of the ADCs (minus the offset)
and the ideal output of the ADCs. The difference is expressed
as a percentage of the ideal output of the ADCs.
Oscillator Frequency Tolerance
The oscillator frequency tolerance of the AD71056 is defined as
the part-to-part frequency variation in terms of percentage
at room temperature (25°C). It is measured by taking the
difference between the measured oscillator frequency and the
nominal frequency as defined in the Specifications section.
Oscillator Frequency Stability
Oscillator frequency stability is defined as the frequency
variation in terms of the parts-per-million drift over the
operating temperature range. In a metering application, the
temperature range is −40°C to +85°C. Oscillator frequency
stability is measured by taking the difference between the
measured oscillator frequency at −40°C and +85°C and the
measured oscillator frequency at +25°C.

Related parts for AD71056ARZ-RL