ADUM5000ARWZ-RL Analog Devices Inc, ADUM5000ARWZ-RL Datasheet - Page 7

no-image

ADUM5000ARWZ-RL

Manufacturer Part Number
ADUM5000ARWZ-RL
Description
Isolated DC/DC Converter
Manufacturer
Analog Devices Inc
Series
IsoPower®, iCoupler®r
Datasheet

Specifications of ADUM5000ARWZ-RL

Design Resources
USB Cable Isolator Circuit (CN0159)
Inputs - Side 1/side 2
2/0
Number Of Channels
2
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Data Rate
-
Propagation Delay
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM5000ARWZ-RL
Manufacturer:
AD
Quantity:
1 670
Part Number:
ADUM5000ARWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 10.
Parameter
Storage Temperature (T
Ambient Operating Temperature (T
Supply Voltages (V
Input Voltage (RC
Output Voltage (RC
Average Total Output Current
Common-Mode Transients
1
2
3
4
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Each voltage is relative to its respective ground.
V
given channel, respectively. See the PCB Layout section.
See Figure 2 for maximum rated current values for various temperatures.
Refers to common-mode transients across the isolation barrier. Common-
mode transients exceeding the absolute maximum ratings may cause
latch-up or permanent damage.
DDI
I
ISO
and V
DDO
refer to the supply voltages on the input and output sides of a
SEL
DDx
OUT
,RC
, V
)
1, 2
IN
ST
ISO
, V
)
)
1
SEL
4
)
1, 2
3
A
)
Rating
−55°C to +150°C
−40°C to +105°C
−0.5 V to +7.0 V
−0.5 V to V
−0.5 V to V
100 mA
−100 kV/μs to +100 kV/μs
DDI
DDO
+ 0.5 V
+ 0.5 V
Rev. A | Page 7 of 16
Table 11. Maximum Continuous Working Voltage
Parameter
AC Voltage
Unipolar Waveform
DC Voltage
1
ESD CAUTION
Refers to continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more details.
Bipolar Waveform
Basic Insulation
Reinforced Insulation
Basic Insulation
Reinforced Insulation
Max
424
600
353
600
353
Unit
V peak
V peak
V peak
V peak
V peak
Reference Standard
50-year minimum
lifetime
Maximum approved
working voltage per
IEC 60950-1
Maximum approved
working voltage per
IEC 60950-1
Maximum approved
working voltage per
IEC 60950-1
Maximum approved
working voltage per
IEC 60950-1
ADuM5000
1

Related parts for ADUM5000ARWZ-RL