Specifications of MM908E625ACDWB
Applications
Automotive Mirror Control
Core Processor
HC08
Program Memory Type
FLASH (16 kB)
Controller Series
908E
Ram Size
512 x 8
Interface
SCI, SPI
Number Of I /o
13
Voltage - Supply
8 V ~ 18 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
54-SOIC (0.300", 7.50mm Width) Exposed Pad
Program Memory Size
16 KB
Number Of Programmable I/os
54
Number Of Timers
16
Operating Supply Voltage
- 18 V to + 28 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
MM908E625ACDWB
Manufacturer:
FREESCALE Semiconductor
Quantity:
26
HALF-BRIDGE OVERTEMPERATURE
PROTECTION
warning with the HTF in the Interrupt Flag Register (IFR). In
order to protect the outputs against overtemperature, the
High-Temperature Reset must be enabled. If this value is
reached, the part generates a reset and disables all power
outputs.
HALF-BRIDGE OVERCURRENT PROTECTION
to VSUP, and load shorts.
the high-side MOSFETs on all HB high-side MOSFETs are
switched off automatically. In the event an overcurrent on the
low side is detected, all HB low-side MOSFETs are switched
off automatically. In both cases the overcurrent status flag
HB_OCF in the System Status Register (SYSSTAT) is set.
enabled) by writing a Logic [1] to the HB_OCF flag in the
System Status Register or by reset.
HALF-BRIDGE OVERVOLTAGE/UNDERVOLTAGE
undervoltage and overvoltage conditions. This protection is
Analog Integrated Circuit Device Data
Freescale Semiconductor
The half-bridge outputs provide an overtemperature pre-
The half-bridges are protected against short to GND, short
In the event an overcurrent on the high side is detected,
The overcurrent status flag is cleared (and the outputs re-
The half-bridge outputs are protected against
1
Figure 20. BEMF Signal Generation
done by the low- and high-voltage interrupt circuitry. If one of
these flags (LVF, HVF) is set, the outputs are automatically
disabled.
(and the outputs re-enabled) by writing a Logic [1] to the LVF/
this flag is useless as long as a high- or low-voltage condition
is present.
HALF-BRIDGE CONTROL REGISTER (HBCTL)
H-Bridge Offset Chopping Enable Bit (OFC_EN)
the OFC_EN bit.
HVF flags in the Interrupt Flag Register or by reset. Clearing
Bits
Reset
Write
Read
The overvoltage/undervoltage status flags are cleared
This read/write bit enables offset chopping. Reset clears
• 1 = Offset chopping enabled
• 0 = Offset chopping disabled
BEMF Signal
Coil Current
Voltage on
OFC_EN
Register Name and Address: HBCTL - $02
7
0
1
CSA
6
0
LOGIC COMMANDS AND REGISTERS
5
0
0
FUNCTIONAL DEVICE OPERATION
4
0
0
3
0
0
CLS2
2
0
CLS1
1
0
908E625
CLS0
0
0