C200H-PS211 Omron, C200H-PS211 Datasheet - Page 194

no-image

C200H-PS211

Manufacturer Part Number
C200H-PS211
Description
EXPAN. P/S: 24VDC
Manufacturer
Omron
Datasheet

Specifications of C200H-PS211

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
7
198
Special Instructions
Failure Alarm
and Reset
FAL(06)
Severe Failure
Alarm
FALS(07)
Message
Display
(@)MSG(46)
Bit Counter
BCNT(67)
Interrupt
Control
(@)FUN(89)
Watchdog Tim-
er Refresh
(@)WDT(94)
I/O Refresh
(@)IORF(97)
Scan Time
(@)SCAN(18)
Mnemonic
Name
FALS(07) N
SCAN(18)
Mi
MSG(46)
FM
IORF(97)
St
E
BCNT(67)
N
SB
R
WDT(94) T
FUN(89)
CC
N
D
FAL(06) N
Symbol
Instruction Set
FAL is displayed on a programming device.
When N is 01 to 99, an error that will not
stop the CPU is indicated by outputting N
(the FAL number) to the FAL output area. If
N is 00, any data in the FAL output area is
cleared and any other FAL number recorded
in memory replaces it. The same FAL
numbers are used for both FAL(06) and
FALS(07).
An error is indicated by outputting N to the
FAL output area and the CPU is stopped.
The same FAL numbers are used for both
FAL(06) and FALS(07).
Displays on the Programming Console,
GPC, or FIT 8 words of ASCII code starting
from FM. All 8 words must be in the same
data area.
Counts number of ON bits in one or more
words (SB: source beginning word) and
outputs result to specified word (R). N:
number of words to be counted . All words to
be counted must be in the same data area.
Controls interrupts. CC: control code
(defines the process); N: Interrupt Module
unit number (004: scheduled interrupt); D:
control data.
Sets the maximum and minimum limits for
the watchdog timer (normally 0 to 130 ms).
New limits:
Maximum time = 130 + (100 x T)
Minimum time = 130 + (100 x (T--1))
Refreshes all I/O words between the start
(St) and end (E) words. Only I/O words may
be designated. Normally these words are
refreshed only once per scan, but refreshing
words before use in an instruction can
increase execution speed. St must be less
than or equal to E.
Sets the minimum scan time, Mi, in tenths of
milliseconds. The possible setting range is
from 0 to 999.0 ms. If the actual scan time is
less than the time set using SCAN(18), the
CPU will wait until the designated time has
elapsed before starting the next scan.
FM+ 7
FM
ABCD........OP
C
A
O
Function
D
B
P
N:
00 to 99
N:
01 to 99
FM:
IR
HR
AR
TC
DM
LR
#
N:
IR
SR
HR
AR
TC
DM
LR
CC:
000 to
002
T:
0 to 63
St/E:
IR
Mi:
IR
SR
HR
AR
LR
TC
DM
#
Operands
SB:
IR
SR
HR
AR
TC
DM
LR
N:
000 to
004
—:
Not used
R:
IR
HR
AR
TC
DM
LR
D:
IR
HR
AR
TC
DM
LR
#
All models
All models
All models
All models
HS-CPU’s
All models
HS-CPU’s
All models
All models
CPU21
CPU23
CPU31
HS-CPU’s
CPU

Related parts for C200H-PS211