C200H-PS211 Omron, C200H-PS211 Datasheet - Page 195

no-image

C200H-PS211

Manufacturer Part Number
C200H-PS211
Description
EXPAN. P/S: 24VDC
Manufacturer
Omron
Datasheet

Specifications of C200H-PS211

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Instruction Set
Long Message
(@)LMSG(47)
Terminal Mode
(@)TERM(48)
Set System
(@)SYS(49)
High-density
I/O Refresh
MPRF(61)
Trace Memory
Sample
TRSM(45)
Average Valve
AVG(*)
Mnemonic
Name
MPRF(61)
St
E
TRSM(45)
SYS(49)
P
AVG(--)
S
N
D
TERM(48)
LMSG(47)
S
D
Symbol
Outputs a 32-character message to either a
Programming Console, or a device
connected via the RS-232C interface. The
output message must be in ASCII beginning
at address S. The destination of the
message is designated in D: 000 specifies
that the message is to be output to the
GPC; 001 specifies the RS-232C interface,
starting with the leftmost byte; and 002
specifies the RS-232C interface, starting
from the rightmost byte.
When the execution condition is ON, the
Programming Console operation mode is
changed to TERMINAL mode. There is no
program command available to change the
mode back to CONSOLE mode. Pressing
the CHNG key on the Programming
Console manually toggles between the two
modes.
SYS(49) must be programmed at program
address 00001 with LD AR 1001 at program
address 00000.
The leftmost 8 bits of P must contain A3.
The status of bits 00, 01, 06, and 07 are
used to control the 4 operating parameters
described below.
If bit 00 of P is ON, the battery check will be
excluded from system error checks.
If bit 01 of P is ON, the PC will enter
MONITOR mode at startup, unless a
Programming Console connected to the
CPU is not set to MONITOR.
If bit 06 of P is ON, the Force Status Hold
Bit (SR 25211) will be effective at startup.
If bit 07 of P is ON, the I/O Status Hold Bit
(SR 25212) will be effective at startup.
Refreshes I/O words allocated to the IR
area Group 2 High-density I/O Modules with
I/O numbers St through E.This will be in
addition to the normal I/O refresh performed
during the CPU’s scan.
MPRF(61) can be used to refresh the I/O
words allocated to the IR area High-density
I/O Modules (IR 030 to IR 049) only.
Normally these words are refreshed only
once per scan, but refreshing words before
use in an instruction can increase execution
speed.
St must be less than or equal to E.
Used in the program to mark locations
where specified data is to be stored in
TRACE memory. Used with LSS only.
Adds the specified number of hexadecimal
words and computes the mean value.
Rounds off the 4-digit past the decimal
point.
Function
Special Instructions
S:
IR
HR
AR
LR
TC
DM
—:
Not used
P:
#
St/E:
# (0000 to 0009)
Not used
S:
IR
SR
AR
DM
HR
TC
LR
Operands
D:
#000
#001
#002
—:
Not used
N:
IR
SR
AR
DM
HR
TC
LR
#
—:
Not
used.
D:
IR
SR
AR
DM
HR
LR
CPU21
CPU23
CPU31
HS-CPU’s
CPU21
CPU23
CPU31
HS-CPU’s
CPU21
CPU23
CPU31
CPU21
CPU23
CPU31
HS-CPU’s
HS-CPU’s
HS-CPU’s
CPU
199
7