DC AMP NPN FOR E2C PROX

E2C-JC4A

Manufacturer Part Number
E2C-JC4A
Description
DC AMP NPN FOR E2C PROX
Manufacturer
Omron
Series
E2Cr
Datasheets

Specifications of E2C-JC4A

Amplifier Type
Standard
Voltage - Supply
10 V ~ 30 V
Output Type
NPN
Current - Supply
45mA
Mounting Type
Bracket Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E2CJC4A
Removing the Amplifier Unit
● Wiring
Self-diagnostic Output
When not using the self-diagnostic output, connect the orange wire to
0 V or cut it and wrap it with insulation tape so that it does not come
into contact with other terminals.
● Miscellaneous
The sensor does not have a water-resistant structure. Do not use it
where it would be subjected to water or water vapor.
• When the Amplifier Unit is mounted using the Y92F-30, loosen the
• Using Y92F-70, Y92F-71
screws on the adapter, spread the hooks at the top and bottom, and
remove the Adapter.
Press in on the hooks with your thumb and forefinger and press
forward on the Amplifier Unit.