G6JU-2P-Y DC3 Omron, G6JU-2P-Y DC3 Datasheet
G6JU-2P-Y DC3
Specifications of G6JU-2P-Y DC3
G6JU2PYDC3
Related parts for G6JU-2P-Y DC3
G6JU-2P-Y DC3 Summary of contents
Page 1
... Application Examples Communications equipment, measurement devices, computer peripheral devices, office automation equipment, and audio-visual products. Model Non-latching Single coil latching G6J-2P-Y G6JU-2P-Y G6J-2FL-Y G6JU-2FL-Y G6J-2FS-Y G6JU-2FS-Y 4. Packaging None: Tube packaging TR: Tape and reel packaging 9. Rated Coil Voltage 3, 4.5, 5, 12, 24 Surface-mounting Relay G6J-Y 57 ...
Page 2
... Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. The operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. G6JU-Y Single coil, Latching (G6JU-2P-Y, G6JU-2FL-Y, G6JU-2FS-Y) Rated voltage Rated current ...
Page 3
... The insulation resistance was measured with a 500-VDC Megger Tester applied to the same parts as those for checking the dielectric strength. 4. The above values are initial values. Standard non-latching relays G6J-2P-Y, G6J-2FS-Y, G6J-2FL max. (approx. 0.9 ms min. (at 100% rated coil voltage) 2 (approx. 100G) 2 (approx. 75G) Surface-mounting Relay Single coil latching relays G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y G6J-Y 59 ...
Page 4
Characteristic Data Maximum Switching Capacity resistive load 1 0.7 0.5 DC resistive load 0.3 0 100 300 500 1,000 Switching voltage (V) Electrical Life Expectancy 1,000 500 300 100 ...
Page 5
Mutual Magnetic Interference Initial Installed in flush stage configuration +30 +20 +10 Sample 0 −10 Not energized −20 Average value −30 Initial Installed in flush stage configuration +30 +20 +10 Sample 0 −10 Energized −20 Average −30 value Set voltage ...
Page 6
Must Operate and Must Release Time Distribution (See note.) 40 Sample: G6J-2P-Y Must Operate time Number of Relays Must Release time 0.5 1 1.5 2 2.5 3 Time (ms) Note: The ...
Page 7
... Orientation mark holes 3.2 − (1.25) G6JU-2P-Y Orientation mark − − Terminal Arrangement/ Internal Connections (Top View) G6J-2FS-Y Orientation mark 2. − 4. G6JU-2FS-Y Orientation mark − − Terminal Arrangement/ Internal Connections (Top View) G6J-2FL-Y Orientation mark 3 − 5 G6JU-2FL-Y Orientation mark − − ...
Page 8
... Surface-mounting Relay Carrier Tape Dimensions G6J-2FS-Y, G6JU-2FS-Y 16± 0.1 2± 4± 0.1 0.1 Stopper (green) A 6.2± 8.3± 0.1 5° max. G6J-2FL-Y, G6JU-2FL-Y 16± 0.1 2± 4± 0.1 A 7.9± 0.1 5° max. Orientation mark Pulling direction dia. 13± 0.2 ± ...
Page 9
... Contact form Coil rating DPDT G6J-2P-Y, 2FS-Y, 2FL- VDC G6JU-2P-Y, 2FS-Y, 2FL- VDC • The thickness of cream solder to be applied should be between 150 and 200 μm on OMRON's recommended PCB pattern. • In order to perform correct soldering recommended that the correct soldering conditions be maintained as shown below on the left-hand side ...
Page 10
Precautions Correct Use Long Term Current Carrying Under a long-term current carrying without switching, the insulation resistance of the coil goes down gradually due to the heat generated by the coil itself. Furthermore, the contact resistance of the Relay will ...
Page 11
... Seller within 30 days of receipt of shipment. III. PRECAUTIONS 1. Suitability THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE BUYER’ ...
Page 12
... THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ...