MKS2XTIN-11 AC24 Omron, MKS2XTIN-11 AC24 Datasheet - Page 2

no-image

MKS2XTIN-11 AC24

Manufacturer Part Number
MKS2XTIN-11 AC24
Description
MKS DC Square Base
Manufacturer
Omron
Datasheet

Specifications of MKS2XTIN-11 AC24

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
2
MK-S(X)
Specifications
Ratings
Operating Coil
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/−20% for AC rated current and
Rated voltage (V)
AC
DC
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. The maximum allowable voltage is the maximum value of the allowable voltage range for the operating power supply for the relay coil.
4. The rated current is approximately 5 mA higher for Models with Built-in Operation Indicators (DC operating coils).
±15% for DC coil resistance.
There is no continuous allowance.
Item
100
110
120
200
220
230
240
110
220
24
12
24
48
Rated current (mA)
110
50 Hz
26.6
24.2
22.2
13.3
12.1
11.5
11.0
126
63.2
32.0
13.6
6.8
60 Hz
96.3
23.1
21.0
19.3
11.6
10.5
10.0
9.6
resistance
32,200
Coil
1,130
3,160
3,550
4,250
4,480
1,500
8,060
(Ω)
760
932
380
95
48.4
voltage (V)
80% max.
operate
Must
Percentage of rated voltage
30% min. at
25% min. at
voltage (V)
15% min.
release
60 Hz
50 Hz
Must
allowable (V)
Maximum
voltage
110%
Approx. 2.3 VA
Approx. 2.7 VA
consumption
Approx. 1.5 W
at 60 Hz
at 50 Hz
(VA, W)
Power