Y92F-40 Omron, Y92F-40 Datasheet

no-image

Y92F-40

Manufacturer Part Number
Y92F-40
Description
PANEL ADAPTER/H3M
Manufacturer
Omron
Series
H3Mr
Datasheet

Specifications of Y92F-40

Accessory Type
Panel Mount Adapter, Frame
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H3M Series
For Use With
H3M-US-DC12-B - TIMER SOLID STATE 12VDC SMDH3M-H-DC12-C - TIMER SOLID STATE SPDT 12VDC SMDH3M-HDC12B - TIMER SOLID STATE SPDT 12VDC SMDH3M-HDC125B - TIMR SOLID STATE SPDT 125VDC SMDH3M-H-AC200/240-D - TIMER SOLID STATE SPDT SMDH3M-HAC200/220/240C - TIMER SOLID STATE SPDT SMDH3M-H-AC120-B - TIMER SOLID STATE SPDT 120V SMDH3M-H-AC100/110/120-C - TIMER SOLID STATE SPDT SMDH3M-H-AC100/110/120-A - TIMER SOLID STATE SPDT SMDH3M-DC24-D - TIMER SOLID STATE DPDT 24VDC SMDH3M-DC24-C - TIMER SOLID STATE DPDT 24VDC SMDH3M-DC24-B - TIMER SOLID STATE DPDT 24VDC SMDH3M-DC24-A - TIMER SOLID STATE DPDT 24VDC SMDH3M-AC24-B - TIMER SOLID STATE DPDT 24V SMDH3M-AC240-C - TIMER SOLID STATE DPDT 240V SMDH3M-AC220-B - TIMER SOLID STATE DPDT 220V SMDH3M-AC200/220/240-D - TIMER SOLID STATE DPDT SMDH3M-AC200/220/240-A - TIMER SOLID STATE DPDT SMDH3M-AC120-E - TIMER SOLID STATE DPDT 120V SMDH3M-AC120-D - TIMER SOLID STATE DPDT 120V SMDH3M-AC120-C - TIMER SOLID STATE DPDT 120V SMDH3M-AC120-B - TIMER SOLID STATE DPDT 120V SMDH3M-AC120-A - TIMER SOLID STATE DPDT 120V SMD
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92F40
Solid-state Timer with Variable Time Ranges
• Four time ranges are selectable per timer unit.
• Wide timing range of 0.05 second to 30 hours can be covered
• Standard surface mounting type is easily convertible to flush
• Requires only 40 x 50 mm for mounting space.
• Equipped with power-ON & time-out indicators.
• All standard models approved by UL, CSA, and LR.
Ordering Information
Note: 1. Specify both the model number and supply voltage when ordering.
■ Accessories (Order Separately)
Adapter
Y92F-40
Specifications
■ Time Ranges
Four time ranges are available for each timer by changing the time range selector switch positions to different combinations.
D
E
A
B
C
Time-limit operation/ self-resetting
Time range code
by a combination of five timer units.
mounting type with the use of a special adapter (Y92F-40).
Time range code
Solid-state Timer
H3M
Operation/resetting system
2. Sockets and adapters for surface/track mounting are available optionally and therefore, place the order for them as necessary.
Timer hold-down clips (F-hook and L-hook) are supplied with the timer.
0.1 to 1 min
0.3 to 3 min
0.05 to 0.5 s
0.1 to 1 s
0.3 to 3 s
DPDT
SPDT
Time-limit contact
1 to 10 min
3 to 30 min
0.5 to 5 s
1 to 10 s
3 to 30 s
---
SPDT
Instantaneous
contact
Time range selector switch
Time multiplying key
H3M
H3M-H
0.05 to 0.5 min
0.1 to 1 min
0.3 to 3 min
0.1 to 1 hrs
0.3 to 3 hrs
Surface mounting
Mounting
H3M with Y92F-40 adapter
H3M-H with Y92F-40 adapter
0.5 to 5 min
1 to 10 min
3 to 30 min
1 to 10 hrs
3 to 30 hrs
Flush mounting
CSM_H3M_DS_E_2_1
1

Related parts for Y92F-40

Y92F-40 Summary of contents

Page 1

... Wide timing range of 0.05 second to 30 hours can be covered by a combination of five timer units. • Standard surface mounting type is easily convertible to flush mounting type with the use of a special adapter (Y92F-40). • Requires only for mounting space. • Equipped with power-ON & time-out indicators. ...

Page 2

... Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h) Electrical: Approved standards UL (File No. E41515), CSA (File No. LR22310) Weight Approx. 100 g Note: For the timer with time range code A, add ± the respective characteristics when the time range selector switches are in the (0.05 to 0.5 s) position. 2 (approx. 100G) 2 (approx. 10G) – ...

Page 3

Engineering Data Load current (A) Operation ■ Timing Chart H3M Rt Set time Set time 7-2 (Power) 1-4 (NC) 1-3 (NO) 8-5 (NC) 8-6 (NO) Power ON indicator lamp Time-out indicator Rt: Resetting time Reference: A maximum current of 0.15 ...

Page 4

... Dimensions Note: All units are in millimeters unless otherwise indicated. H3M(-H) ■ Accessories (Order Separately) Y92F-40 Adapter with Flush Mounting 63.5 75.5 Note: When two or more timers mounted in line are to be continuously energized at the same time after the lapse of the set time, be sure to limit the carry current to less than 1 A. When using the timers at an ambient temperature of more than 40° ...

Page 5

Back Connecting Socket PL08 Two, 2 dia. holes P3G-08 Mounting Track PFP-100N/PFP-50N (See note) Note: This dimension applies to PFP-50N. Terminal Arrangement Mounting Holes (Bottom View) Two, 3.5 dia socket mounting holes Terminal Arrangement (Bottom View) End Plate ...

Page 6

... How to Change the Time Range The H3M is provided with two time range selector switches. One is on the lower right side A of the front panel and the other on the lower left side. Change the positional combination of the time range selector switches with a flat-blade screwdriver as desired ...

Page 7

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords