Specifications of Y92F-40

Accessory Type
Panel Mount Adapter, Frame
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H3M Series
For Use With
H3M-US-DC12-B - TIMER SOLID STATE 12VDC SMDH3M-H-DC12-C - TIMER SOLID STATE SPDT 12VDC SMDH3M-HDC12B - TIMER SOLID STATE SPDT 12VDC SMDH3M-HDC125B - TIMR SOLID STATE SPDT 125VDC SMDH3M-H-AC200/240-D - TIMER SOLID STATE SPDT SMDH3M-HAC200/220/240C - TIMER SOLID STATE SPDT SMDH3M-H-AC120-B - TIMER SOLID STATE SPDT 120V SMDH3M-H-AC100/110/120-C - TIMER SOLID STATE SPDT SMDH3M-H-AC100/110/120-A - TIMER SOLID STATE SPDT SMDH3M-DC24-D - TIMER SOLID STATE DPDT 24VDC SMDH3M-DC24-C - TIMER SOLID STATE DPDT 24VDC SMDH3M-DC24-B - TIMER SOLID STATE DPDT 24VDC SMDH3M-DC24-A - TIMER SOLID STATE DPDT 24VDC SMDH3M-AC24-B - TIMER SOLID STATE DPDT 24V SMDH3M-AC240-C - TIMER SOLID STATE DPDT 240V SMDH3M-AC220-B - TIMER SOLID STATE DPDT 220V SMDH3M-AC200/220/240-D - TIMER SOLID STATE DPDT SMDH3M-AC200/220/240-A - TIMER SOLID STATE DPDT SMDH3M-AC120-E - TIMER SOLID STATE DPDT 120V SMDH3M-AC120-D - TIMER SOLID STATE DPDT 120V SMDH3M-AC120-C - TIMER SOLID STATE DPDT 120V SMDH3M-AC120-B - TIMER SOLID STATE DPDT 120V SMDH3M-AC120-A - TIMER SOLID STATE DPDT 120V SMD
Color
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Y92F40
■ Ratings
Note: 1. Color indicators for the rated voltage are provided on the front of the Timer.
■ Characteristics
Note: For the timer with time range code A, add ±10 ms to the respective characteristics when the time range selector switches are in the x 1 s
Rated supply voltage
Operating voltage range
Power consumption
Control outputs
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Approved standards
Weight
2. With DC ratings, single-phase full-wave rectified power sources may be used.
3. 90% to 110% for 12-VDC models.
(0.05 to 0.5 s) position.
Blue: 100/110/120 VAC
Red: 200/220/240 VAC
None: Other voltages
100/110/120 VAC (50/60 Hz), 200/220/240 VAC (50/60 Hz),
12, 24, 48, 100, 110 VDC (see note 2)
AC: 85% to 110% of rated supply voltage
DC: 80% to 110% of rated supply voltage (see note 3)
AC: Approx. 5 VA/2 W
DC: Approx. 2 W
5 A at 250 VAC, resistive load (cosφ = 1)
±1% max. (see note)
±10% max.
0.1 s max.
±1% max. (see note)
±2% max. (see note)
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)
1,500 VAC, 50/60 Hz for 1 min (between contact and control circuit)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 100 m/s
Operating:
Storage:
Operating: 35% to 85%
Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
UL (File No. E41515), CSA (File No. LR22310)
Approx. 100 g
–10°C to 50°C
–25°C to 65°C
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
2
(approx. 10G)
2
(approx. 100G)
H3M