JQ1AP-18V-F PANASONIC EW, JQ1AP-18V-F Datasheet - Page 2

no-image

JQ1AP-18V-F

Manufacturer Part Number
JQ1AP-18V-F
Description
JQ Relay (Cd-Free)
Manufacturer
PANASONIC EW
Datasheet
JQ
Characteristics
Remarks
* Specifications will vary with foreign standards certification ratings.
*
*
*
*
*
*
*
*
*
*
TYPICAL APPLICATIONS
• Air conditioners
• Refrigerators
• Microwave ovens
• Heaters
ORDERING INFORMATION
UL/CSA, VDE, SEMKO approved type is standard.
Notes:
Max. operating speed
Initial insulation resistance*
Initial breakdown voltage*
Surge voltage between contact and coil*
Operate time*
Release time*
Temperature rise*
Shock resistance
Vibration resistance
Conditions for operation, transport and storage*
(Not freezing and condensing at low temperature)
Unit weight
1
2
3
4
5
Standard type
High capacity type
6
7
8
9
10
Measurement at same location as “Initial breakdown voltage” section
Detection current: 10 mA
Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
Excluding contact bounce time
Measured conditions
Half-wave pulse of sine wave: 11ms; detection time: 10µs
Half-wave pulse of sine wave: 6ms
Detection time: 10µs
Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C
68°F
1a: 1 Form A
1: 1 Form C
arrangement
1. Standard packing: Carton: 100 pcs. Case: 500 pcs.
2. *Available only for 1 Form C type
3. Please inquire about the previous products (Cadmium containing parts).
as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range.
Contact
4
4
(at nominal voltage) (at 20°C 68°F)
(at nominal voltage) (without diode) (at 20°C 68°F)
5
(coil)
2
1
Contact capacity
Nil: Standard
P: High capacity
Between open contacts
Between contacts and coil
Functional*
Destructive*
Functional*
Destructive
Resistance method, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70°C
Resistance method, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70°C
Ex.
3
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
JQ
9
6
8
7
1a
Ambient temp.*
Humidity
Nil: Class E coil insulation
B: Class B coil insulation
Coil insulation class
P
10
B
12
V
10 to 55 Hz at double amplitude of 1.6 mm
10 to 55 Hz at double amplitude of 2.0 mm
5, 6, 9, 12, 18, 24, 48* V
F
–40°C to +85°C
Coil voltage (DC)
Min. 1,000 MΩ at 500 V DC
1a: 1,000 Vrms for 1 min.
1c: 750 Vrms for 1 min.
4,000 Vrms for 1 min.
Approx. 7 g
980 m/s
294 m/s
5 to 85% R.H.
Max. 20 ms
Max. 10 ms
Max. 45°C
8,000 V
20 cpm
2
–40°F to +185°F
2
{100 G}
{30 G}
.25 oz
158°F
158°F
Contact material
F: AgSnO
33.8°F
2
type
with 20°C

Related parts for JQ1AP-18V-F