JQ1AP-18V-F PANASONIC EW, JQ1AP-18V-F Datasheet - Page 5

no-image

JQ1AP-18V-F

Manufacturer Part Number
JQ1AP-18V-F
Description
JQ Relay (Cd-Free)
Manufacturer
PANASONIC EW
Datasheet
High capacity type
1-(1). Operate & release time (1 Form A type)
Tested sample: JQ1aP-12V-F, 25 pcs.
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
4-(1). Ambient temperature characteristics
(1 Form A type)
Tested sample: JQ1aP-24V-F
Contact carrying current: 5 A, 10 A
NOTES
Note about relay installation orientation
For Cautions for Use, see Relay Technical Information.
400
300
200
100
70
60
50
40
30
20
10
0
8
6
4
2
0
0
100
80
20
10 A at 70°C
5
30
120
6
100
1
Coil applied voltage, %V
Coil applied voltage, %V
Ambient temperature, °C
40
5 A at 85°C
Operate time
Release time
3
2
140
50
120
10 A at 85°C
7
4
60
5 A at 70°C
160
Bottom
70
Top
80
180
150
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Max.
Min.
Max.
Min.
90
1-(2). Operate & release time (1 Form C type)
Tested sample: JQ1P-12V-F, 25 pcs.
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 5 A, 10 A
Measured portion: Inside the coil
4-(2). Ambient temperature characteristics
(1 Form C type)
Tested sample: JQ1P-24V-F
Contact carrying current: 5 A, 10 A
When installing with the relay terminals
parallel to the ground, the contact
terminals at the bottom and the coil
terminals at the top, component friction
will occur after numerous switching
actions or due to vibration in the non-
excitation state. Since this may cause the
relay to stop functioning when the pick-up
voltage increases even if the nominal
voltage is applied, please do not install
using this orientation.
400
300
200
100
70
60
50
40
30
20
10
8
6
4
2
0
0
0
80
100 110 120 130 140 150 160
20
10 A at 70°C
1
5
30
6
100
Coil applied voltage, %V
2
Coil applied voltage, %V
Ambient temperature, °C
40
5 A at 85°C
Operate time
Release time
10 A at 85°C
50
7
120
3
60
5 A at 70°C
4
70
80
150
Max.
Max.
Min.
Min.
90
2. Life curve
Ambient temperature: room temperature
1 Allowable ambient temperature against
2 Allowable ambient temperature against
3 Allowable ambient temperature against
4 Allowable ambient temperature against
5 Pick-up voltage with a hot-start condition
6 Pick-up voltage with a hot-start condition
7 Pick-up voltage
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 5 A)
% coil voltage (max. inside the coil temperature
set as 130°C 266°F) (Carrying current: 10 A)
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 5 A)
% coil voltage (max. inside the coil temperature
set as 115°C 239°F) (Carrying current: 10 A)
of 100%V on the coil (Carrying current: 10 A)
of 100%V on the coil (Carrying current: 5 A)
100
10
1
0
250V AC resistive load
2
4
Contact current, A
125V AC resistive load
6
8
JQ
10

Related parts for JQ1AP-18V-F