CJ1W-AD04U Omron, CJ1W-AD04U Datasheet - Page 3

no-image

CJ1W-AD04U

Manufacturer Part Number
CJ1W-AD04U
Description
Isolated Universal Analog 4pt
Manufacturer
Omron
Datasheet

Specifications of CJ1W-AD04U

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
4
Loop-control CPU Unit
Temperature
input
Read data from
Analog Input
Field Terminal
Engineering Example: Program Control
Analog Input
X1
Segment
Program 2
SP
Units
Analog
Input
Unit
Input
channel 1
PV
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
Y1
Y2
RSP
Heater output
Sequence control programs: Standardize and simplify programs using structured programming. Special I/O
Unit and CPU Bus Unit settings are easy with function blocks (using ladder programming language or
structured text).
Loop control programs: By combining function blocks, a wide array of control methods can be easily
configured, from basic PID control used by Temperature Controllers to program, cascade, and feed-forward
control. Easily display values, such as temperatures, in engineering units, allowing you to check operation.
Loop control: Programming with function blocks to suit the application.
System configuration: Choose and combine functions from a broad selection of I/O Units.
TIC
channel 1
Perform program
Output
Analog
Output
MV
Function blocks make loop-control programming easy. You can also create
CX-Process Tool tuning windows to help adjust loops. Controller faceplates
can be created automatically for touch panel displays.
Unit
control
Time
PV
RSP
Perform PID
Basic PID
control
SP
DV
MV
Set point (SP)
T0
T1 T2
CX-Process Tool (Software for Personal Computer)
1
Combine function blocks and connect graphically
using the mouse.
Analog Input
Field Terminal
Segment
Program
T3
Split Conversion
heating/cooling
Y1
Y2
Y3
Y4
X1
Y1
Perform
T4
control
Lineup includes low-cost models that use up to 50 function
blocks and models that allow up to 300 blocks designed for
large-scale systems and complicated operations.
T5
Y1
Y2
RSP
PV
2
Basic PID
Adjust PID and other parameters
T6
in the tuning window.
MV
T97 T98 T99 T100
Analog Output
Field Terminal
Control output
from Analog
X1
X2
X3
X4
X5
X6
X7
X8
Output Unit
Analog Output
Field Terminal
X1
X2
X3
X4
TIME
Face Plate Auto-Builder for NS
3
Touch panel windows are automatically generated.
Loop-control CPU Unit
NT-series PT
Note: CJ1G-CPU44P/45P
(CJ1G-CPU42P/43P: Expand up to 2 Racks)
System Configuration
Expansion Rack
Expansion Rack
Expansion Rack
Serial or
Ethernet
communications
10 Units max.
10 Units max.
10 Units max.
10 Units max.
Control window
Tuning window
Segment program
parameter setting window
Process Input
Units, Analog
I/O Units, etc.
Expansion
Rack: 3
Racks
max.
(See note.)
New Algorithm Further Enhances Control
Stability
Optimum Tuning to Suit the Application
Disturbance Overshoot Adjustment
Fine Tuning
This function restrains overshoot when a disturbance is
generated, allowing faster stabilization.
[Example]
• Temperature drops when adding objects to a furnace
• Control disturbances when retooling
Adjust PVs, SPs, and MVs while monitoring, and save
data as CSV files from the software tuning window.
Autotuning (AT) and fine-tuning functions can also be
used for automatically calculating PID constants (see note
2).
Note 1: For details on CS-series Loop Control Boards, refer to the PLC-based
2: Control can be fine-tuned by automatically tuning PID parameters using
Process Control Catalog (Cat. No. P051).
previous control parameters and three user-set requirements to execute
fuzzy logic.
Simple backup function enables backup, recovery, and comparison of all PLC data including the
function block programs for the Loop Control Board using the Memory Card.
Save tag settings, comments, annotations, and connection data created using the CX-Process
Tool to either a Memory Card or a Loop-control CPU Unit.
Loop control: Proven functionality of Temperature Controllers and CS-series Loop Control
Boards (see note 1) in a compact size.
Consolidating OMRON's expertise in temperature and process control
cultivated over many years to provide you with effortless solutions
using proven algorithms.
Press the
Memory Card
power supply
switch for 3 s.
Simply turn the DIP Switch ON/OFF to save or read the
user program including function blocks using the
Memory Card.
Disturbance generated
CS-Process Tool Tuning Window
Disturbance
Time required to
stabilize
Overshoot
Note: Supported by unit version 3.0 or later.
CPU Unit
Condition: Pin 7 is ON
Sequence
Parameter Area
program
I/O memory
Function
program
block
Conventional PID gain adjustment
Using the Disturbance
Overshoot Adjustment function
Longer time required
to stabilize
Faster stabilization
Memory
Simple backup
to Memory
Card, including
function block
data.
Card
5

Related parts for CJ1W-AD04U