Specifications of CS1W-V680C12

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
■ CS1D Long-distance Expansion Racks
A Long-distance Expansion System can connect a Rack at a distance of up to 50 m. The Long-distance Expansion System functions can be used
in the Duplex CPU Single I/O Expansion System and Single CPU System. Special I/O Control Units and I/O Interface Units are used.
System Configuration Diagram
List of Required Devices
Limitations on the System Configuration
Note: 1. These Racks cannot be used in a Duplex CPU Dual I/O Expansion System.
24
CS1D-BI092
CS1D Expansion Backplane
CS1D-BI092
CS1D Expansion Backplane
CS1D-BI092
CS1D Expansion Backplane
Note: If even one CV500-CN@@2 Cable for Long-distance Expansion is used in the PLC system, an I/O Control Unit is required in the source
CPU Rack
Expansion Rack CS1D-BI092 Expansion Backplane (for Duplex CPU Single I/O Expansion Systems or Single CPU Systems)
CS1D-BI092
CS1D Expansion Backplane
Rack
Rack
2. The following functions cannot be used: Duplex Expansion Cables, Online replacement of a Duplex Unit, Online replacement of Units
CS1 Rack.
without a Programming Device, and Online addition of I/O Units and Expansion Backplanes. If any of these functions are required, a
Duplex CPU, Dual I/O Expansion System must be used.
Programmable Controllers SYSMAC
CS1D-IC102 I/O Control Unit (for Duplex CPU Single I/O Expansion Systems and Single CPU Systems)
Maximum number of Configuration Units
CS1D-PA207R/CS1D-PD02@ Power Supply Unit
CS1W-II102 I/O Interface Unit (for Duplex CPU Single I/O Expansion Systems or Single CPU Systems)
Maximum number of Configuration Units
50 m
Expansion Cable connector:
Expansion Unit Slot
Connect the Expansion Unit Interface Cables.
Only an Expansion Unit can be mounted.
CV500-CN@@2
CV-series Connecting Cable
CS1W-II102
I/O Interface Unit
CS1W-II102
I/O Interface Unit
CS1W-II102
I/O Interface Unit
CS1W-II102
I/O Interface Unit
CS1W-IC102
I/O Control Unit
(See note.)
IC102
RDY
TER ERR
CS
IC102
IC102
IC102
IC102
RDY
TER ERR
RDY
TER ERR
RDY
TER ERR
RDY
TER ERR
CS
CS
CS
CS
CV500-CN@@2
CV-series Connecting Cable
CV500-CN@@2
CV-series Connecting Cable
CV500-CN@@2
CV-series Connecting Cable
Terminator
DUPLEX
LEFT CPU
INIT.
RIGHT CPU
DPL SW
ON
ON
SW
CS1D CPU Rack
CS1D
Expansion Rack
CS1D
Expansion Rack
CS1D
Expansion Rack
CS1D
Expansion Rack
(Single CPU System or
Duplex CPU System)
CS1D-P@@@@(@)
Power Supply Units
CV500-CN@@2
CV-series Connecting Cable
Duplex CPU Single I/O Expansion System
Single CPU System
CS1D
I/O Unit slots:
The following Units can be mounted.
CS1 Basic I/O Units
CS1 Special I/O Units
CS1 CPU Bus Units
Unit name
Unit name
CS1W-II102
I/O Interface Unit
CS1W-II102
I/O Interface Unit
CS1W-II102
I/O Interface Unit
IC102
IC102
IC102
RDY
TER ERR
RDY
TER ERR
RDY
TER ERR
CS
CS
CS
CV500-CN@@2
CV-series Connecting Cable
CV500-CN@@2
CV-series Connecting Cable
Terminator
CS1D
Expansion Rack
CS1D
Expansion
Rack
CS1D
Expansion
Rack
50 m
CS1D-P@@@@(@)
Power Supply Units
Power Supply Unit slots:
The maximum number
of Expansion Racks: 7 (In two levels)
CS1D Power Supply Units
can be mounted.
Maximum Expansion Racks
CS1D-CPU6@H
CS1D-CPU6@P
Model
Expansion Rack
7 Racks
Maximum No. of Racks
1 Backplane
2 Units (Just 1 Unit can
also be used.)
1 Unit
8 Units
1 Unit
4 Units
7 Units
Number required
Number required