Common Specifications
34
Control method
I/O control method
Programming
Instruction length
Ladder instructions
Instruction
execution
times
Number of Tasks
Interrupt types
Note: The interrupts can be used in
Function blocks
CIO (Core I/O)
Area
Work Areas
Holding Area
Auxiliary Area
Temporary Relay (TR) Area
Timer Area
Counter Area
Data Memory (DM) Area
Extended Data Memory (EM) Area
Data Registers
Index Registers
CS1D-CPU@@S CPU Units only.
Programmable Controllers SYSMAC
Basic instructions
Special instructions
I/O Area
Data Link Area
CPU Bus Unit Area
Special I/O Unit Area
Inner Board Area
SYSMAC BUS Area
I/O Terminal Area
Internal I/O Area
Work Area
Item
Stored program
Cyclic scan and immediate processing are both supported.
Ladder diagram
1 to 7 steps per instruction
Approx. 400 (3-digit function codes)
0.02 µ s min.
0.04 µ s min.
288 (256 of these tasks are shared with interrupt tasks)
Note: 1. Cyclic tasks are executed each cycle and are controlled with TKON(820) and TKOF(821) instructions.
Scheduled Interrupts: Interrupts generated by the CPU Unit's built-in timer at regular intervals.
I/O Interrupts: Interrupts from Interrupt Input Units
Power OFF Interrupts: Interrupts executed when the CPU Unit's power is turned OFF.
External I/O Interrupts: Interrupts from the Special I/O Units, CS-series CPU Bus Units, or the Inner Board.
Not supported.
5,120: CIO 000000 to CIO 031915 (320 words from CIO 0000 to CIO 0319)
3,200 (200 words): CIO 10000 to CIO 119915 (words CIO 1000 to CIO 1199)
Link bits are used for data links and are allocated to Units in Controller Link Systems.
6,400 (400 words): CIO 150000 to CIO 189915 (words CIO 1500 to CIO 1899)
These words are allocated to CS1 CPU Bus Units.
15,360 (960 words): CIO 200000 to CIO 295915 (words CIO 2000 to CIO 2959)
These words are allocated to CS1 Special I/O Units.
1,600 (100 words): CIO 190000 to CIO 199915 (words CIO 1900 to CIO 1999)
Inner Board bits can be allocated to Inner Boards.
800 (50 words): CIO 300000 to CIO 304915 (words CIO 3000 to CIO 3049)
(Can be used as work words in the program.)
512 (32 words): CIO 310000 to CIO 313115 (words CIO 3100 to CIO 3131)
(Can be used as work words in the program.)
4,800 (300 words): CIO 120000 to CIO 149915 (words CIO 1200 to CIO 1499)
37,504 (2,344 words): CIO 380000 to CIO 614315 (words CIO 3800 to CIO 6143)
These bits in the CIO Area are used as work bits in programming to control program execution. They cannot be used for
external I/O.
8,192 bits (512 words): W00000 to W51115 (W000 to W511)
These bits are used to control the programs only. (I/O from external I/O is not possible.)
8,192 bits (512 words): H00000 to H51115 (H000 to H511)
Holding bits are used to control the execution of the program, and maintain their ON/OFF status when the PLC is turned
OFF or the operating mode is changed.
Read only: 7,168 bits (448 words): A00000 to A44715 (words A000 to A447)
Read/write: 8,192 bits (512 words): A44800 to A95915 (words A448 to A959)
Auxiliary bits are allocated for specific functions.
16 bits (TR0 to TR15)
Temporary bits are used to temporarily store the ON/OFF execution conditions at program branches.
4,096: T0000 to T4095 (used for timers only)
4,096: C0000 to C4095 (used for counters only)
32 Kwords: D00000 to D32767
Special I/O Unit DM Area: D20000 to D29599 (100 words × 96 Units)
Used to set parameters for Special I/O Units.
CPU Bus Unit DM Area: D30000 to D31599 (100 words × 16 Units)
Used to set parameters for CPU Bus Units.
Inner Board DM Area: D32000 to D32099
Used to set parameters for Inner Boards (Single CPU Systems only).
Used as a general-purpose data area for reading and writing data in word units (16 bits).
Words in the DM Area maintain their status when the PLC is turned OFF or the operating mode is changed.
32 Kwords per bank, 13 banks max.: E0_00000 to EC_32767 max. (Not available on some CPU Units.)
Used as a general-purpose data area for reading and writing data in word units (16 bits). Words in the EM Area maintain
their status when the PLC is turned OFF or the operating mode is changed.
DR0 to DR15
Used to offset the PLC memory addresses in Index Registers when addressing words indirectly.
(Data registers can be set to be used independently by each task. One register is 16 bits (1 word).
IR0 to IR15
Store PLC memory addresses for indirect addressing. One register is 32 bits (2 words).
2. The following 4 types of interrupt tasks are supported in CS1D-CPU@@S CPU Units for Single CPU Systems.
(Interrupt tasks are not supported in the CS1D-CPU@@H CPU Units, which are for Duplex CPU Systems.)
Power OFF interrupt tasks: 1 max.
Scheduled interrupt tasks: 2 max.
I/O interrupt tasks: 32 max.
External interrupt tasks: 256 max.
CS1D