ZEN-10C2AR-A-V2 Omron, ZEN-10C2AR-A-V2 Datasheet - Page 30

100/240 VAC 6 IN, 4 OUT

ZEN-10C2AR-A-V2

Manufacturer Part Number
ZEN-10C2AR-A-V2
Description
100/240 VAC 6 IN, 4 OUT
Manufacturer
Omron
Series
ZEN V2r
Type
Expandabler

Specifications of ZEN-10C2AR-A-V2

Voltage - Supply
100 ~ 240VAC
Number Of I /o
6 Input, 4 Output
Display Type
LED
Output Type
Relay
Voltage Rating
100 V to 240 V
Input Type
AC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Kit Contents
-
Analog Inputs
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
Z2680
ZEN10C2ARAV2
2.2 Structure of Command Text
14
SECTION 2 CompoWay/F Communications Protocol
PDU Structure
Addresses
Number of Elements
• An MRC (Main Request Code) and SRC (Sub-Request Code) followed
• The MRES (Main Response Code), SRES (Sub-Response Code),
• If the specified command text could not be executed, the service
by the various required data are transferred in the command text.
Service Request PDU
followed by the data are transferred following the above MRC/SRC in
the response frame.
Service Response PDU (Normal Response)
response PDU will contain only the MRC/SRC and MRES/SRES.
Note: MRES/SRES provides the response code. MRES/SRES is not
Service Response PDU (Command Text Not Executed)
An address is appended to each of the variable types. Express
addresses in 2-byte hexadecimal and append them for the specified
access size.
Specify the number of elements as “0001” (fixed). The number of
elements is expressed in 2-byte hexadecimal.
MRC SRC
MRC SRC
MRC SRC
output when processing ends in a normal completion.
MRES SRES
MRES SRES
Data
Data